Learn Mode Water Resistant Pendant Panic Button Installation Instructions
Programming
This section describes the basic steps for adding the sensor to
panel memory. For complete instructions, refer to the specific
panel’s documentation.
To program the sensor:
1. Set the panel in program mode.
2. When prompted by the panel, enter the appropriate group
number (groups 00 through 07).
Note: For UL installations where the holder is used, the
sensor must be added as a fixed type (sensor groups 00,
02, 04, or 05).
3. When prompted by the panel, select the desired sensor
number.
4. When prompted by the panel, trip the sensor by pressing
the sensor button.
5. Exit from program mode.
Sensor test
To test the sensor:
1. Set the system to the Dealer Sensor Test mode.
2. Press the button on the sensor.
3. Count the number of signals received by the panel,
indicated by interior siren beeps. Seven to eight beeps are
considered acceptable.
4. Test the sensor from several locations within the premises
to check for consistent response.
Battery replacement
To replace the sensor battery:
1. To disassemble the sensor, remove the two screws on the
back of the sensor and separate the front and back plastic.
Caution:
You must be free of static electricity before handling
the transmitter circuit board. Touch a grounded, bare metal
surface before touching the circuit board, or wear a grounding
strap.
2. Remove the old battery from its holder and install the new
battery, observing polarity
Caution:
Install only the same size and type of battery. Do not
substitute another size or type of battery.
3. Reassemble the sensor.
Note: Be sure to assemble the sensor correctly to ensure
water resistance. Be especially careful not to nick or
damage the rubber gasket lining.
4. Test the sensor as described in “Sensor test” above.
Lithium battery disposal
Lithium batteries that are no longer usable are considered
hazardous waste. Be sure to properly dispose of the old
battery. Contact your local city government for hazardous
waste disposal laws.
Specifications
Compatibility
All Interlogix Security Learn Mode panels
Power source
3.6 VDC Saft or Tekcell lithium battery
Enclosure
Water-resistant and shock-resistant
Dimensions (LxWxD)
2.25 x 1.75 x 0.75 in. (5.71 x 4.44 x 1.90 cm)
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943,
USA
1275 Red Fox Rd., Arden Hills, MN 55112-6943,
USA
FCC compliance
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
Changes or modifications not expressly approved
by Interlogix can void the user’s authority to
operate the equipment.
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
Changes or modifications not expressly approved
by Interlogix can void the user’s authority to
operate the equipment.
FCC ID: B4Z-612-H2OPANIC
IC compliance
IC: 1175C-612PANIC
This Class B digital apparatus complies with
Canadian ICES-003.
Cet appareil numérique de la classe B est
conforme à la norme NMB-003 du Canada.
Le fonctionnement est soumis aux deux
conditions suivantes : (1) cet appareil peut ne pas
provoquer d’interférences et (2) cet appareil doit
accepter toutes interférences, y compris les
interférences pouvant provoquer un
fonctionnement non désiré de l’appareil.
Canadian ICES-003.
Cet appareil numérique de la classe B est
conforme à la norme NMB-003 du Canada.
Le fonctionnement est soumis aux deux
conditions suivantes : (1) cet appareil peut ne pas
provoquer d’interférences et (2) cet appareil doit
accepter toutes interférences, y compris les
interférences pouvant provoquer un
fonctionnement non désiré de l’appareil.
U.S. patents
4,855,713, 4,864,636, and others pending.
Contact information
For contact information, see www.utcfireandsecurity.com or
www.interlogix.com.
For technical support, toll-free: 888.437.3287 in the US
including Alaska, Hawaii, Puerto Rico, and Canada. Outside
the toll-free area, contact your dealer.
Copyright © 2014 Interlogix, a UTC Fire & Security Company.
All rights reserved.