Learn Mode Water Resistant Pendant Panic Button Installation Instructions 
Programming 
This section describes the basic steps for adding the sensor to 
panel memory. For complete instructions, refer to the specific 
panel’s documentation. 
To program the sensor: 
1.  Set the panel in program mode. 
2.  When prompted by the panel, enter the appropriate group 
number (groups 00 through 07). 
Note: For UL installations where the holder is used, the 
sensor must be added as a fixed type (sensor groups 00, 
02, 04, or 05). 
3.  When prompted by the panel, select the desired sensor 
number. 
4.  When prompted by the panel, trip the sensor by pressing 
the sensor button. 
5.  Exit from program mode. 
Sensor test 
To test the sensor: 
1.  Set the system to the Dealer Sensor Test mode. 
2.  Press the button on the sensor. 
3.  Count the number of signals received by the panel, 
indicated by interior siren beeps. Seven to eight beeps are 
considered acceptable. 
4.  Test the sensor from several locations within the premises 
to check for consistent response. 
Battery replacement 
To replace the sensor battery: 
1.  To disassemble the sensor, remove the two screws on the 
back of the sensor and separate the front and back plastic. 
Caution: 
You must be free of static electricity before handling 
the transmitter circuit board. Touch a grounded, bare metal 
surface before touching the circuit board, or wear a grounding 
strap. 
2.  Remove the old battery from its holder and install the new 
battery, observing polarity 
Caution: 
Install only the same size and type of battery. Do not 
substitute another size or type of battery. 
3.  Reassemble the sensor. 
Note: Be sure to assemble the sensor correctly to ensure 
water resistance. Be especially careful not to nick or 
damage the rubber gasket lining. 
4.  Test the sensor as described in “Sensor test” above. 
Lithium battery disposal 
Lithium batteries that are no longer usable are considered 
hazardous waste. Be sure to properly dispose of the old 
battery. Contact your local city government for hazardous 
waste disposal laws. 
Specifications 
Compatibility 
All Interlogix Security Learn Mode panels 
Power source 
3.6 VDC Saft or Tekcell lithium battery 
Enclosure 
Water-resistant and shock-resistant 
Dimensions (LxWxD) 
2.25 x 1.75 x 0.75 in. (5.71 x 4.44 x 1.90 cm)
Regulatory information 
Manufacturer 
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943, 
USA 
FCC compliance 
This device complies with part 15 of the FCC 
Rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful 
interference, and (2) this device must accept any 
interference received, including interference that 
may cause undesired operation.  
Changes or modifications not expressly approved 
by Interlogix can void the user’s authority to 
operate the equipment. 
FCC ID: B4Z-612-H2OPANIC 
IC compliance 
IC: 1175C-612PANIC 
This Class B digital apparatus complies with 
Canadian ICES-003.  
Cet appareil numérique de la classe B est 
conforme à la norme NMB-003 du Canada.  
Le fonctionnement est soumis aux deux 
conditions suivantes : (1) cet appareil peut ne pas 
provoquer d’interférences et (2) cet appareil doit 
accepter toutes interférences, y compris les 
interférences pouvant provoquer un 
fonctionnement non désiré de l’appareil.  
U.S. patents 
4,855,713, 4,864,636, and others pending. 
Contact information 
For contact information, see www.utcfireandsecurity.com or 
www.interlogix.com. 