5.1
Setting the loop address
Use the address dip switch ADDR to configure the RS-485 loop address of the receiver. Each
coordinator/receiver on a loop must have its own unique address. Only addresses 0 through
15 are valid.
The coordinator always uses address 0. You do not need to set the address for the
coordinator. Therefore, the dip switch ADDR is not available on the coordinator.
The receivers use addresses 1 to 15. Configure the four switches from the left, 1, 2, 3 and 4 of
dip switch ADDR as the address of the device.
Address
Switch Number on Dip Switch ADDR
1
2
3
4
0
(used for coordinator only)
OFF
OFF
OFF
OFF
1
(default setting for receiver)
ON
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
3
ON
ON
OFF
OFF
4
OFF
OFF
ON
OFF
5
ON
OFF
ON
OFF
6
OFF
ON
ON
OFF
7
ON
ON
ON
OFF
8
OFF
OFF
OFF
ON
9
ON
OFF
OFF
ON
10
OFF
ON
OFF
ON
11
ON
ON
OFF
ON
12
OFF
OFF
ON
ON
13
ON
OFF
ON
ON
14
OFF
ON
ON
ON
15
ON
ON
ON
ON
Tab. 5.6: Address settings on dip switch ADDR
5.2
Selecting the hard/soft reset mode
There are two reset modes for the coordinator/receiver, namely the hard or soft reset. To
select the reset mode, use dip switch CFG1. Set switch number 3 based on the following
table.