Robert Bosch Security Solutions Pte Ltd COR-RCV-433 Manuel D’Utilisation

Page de 32
24
en | Setting the Switches and Jumpers
Security Escort Coordinator & Receiver
2017.08 | SE3v1.0 | F.01U.277.701
Installation Manual
Robert Bosch (SEA) Pte Ltd
Reset Mode
Switch Number on Dip Switch CFG1
3
Soft reset (default setting)
OFF
Hard reset
ON
Tab. 5.7: Reset mode on dip switch CFG1
Pressing the Reset button on the coordinator/receiver performs the hard or soft reset
accordingly. The differences of the reset mode are described in Resetting the coordinator/
receiver, page 27
.
5.3
Setting the baud rate
Configure the baud rate of the RS-485 communication by using the dip switch CFG1. The
same baud rate must be set across the coordinator and the receivers in order for the RS-485
communication to work. Use the switch numbers 4 and 5 on dip switch CFG1 to set the baud
rate. The options are described in the following table.
Baud Rate
Switch Number on Dip Switch CFG1
4
5
19200 (default setting)
OFF
OFF
38400
OFF
ON
57600
ON
OFF
115200
ON
ON
Tab. 5.8: Setting the baud rate on dip switch CFG1
5.4
Enable/disable the buzzer
Enable or disable the buzzer by setting the buzzer dip switch.
Set switch number 6 on dip switch CFG1 to the OFF position to disable the buzzer. Once
disabled, the buzzer will be muted at all times, including during alarm events.
Set switch number 6 on dip switch CFG1 to the ON position to enable the buzzer to be
operational. Once enabled, the buzzer will sound whenever triggered accordingly by the alarm
events.
Enable/disable Buzzer
Switch Number on Dip Switch CFG1
6
Disable Buzzer (default setting)
OFF
Enable Operational Buzzer
ON
Tab. 5.9: Enable or disable the buzzer on dip switch CFG1
5.5
Enable/disable the spacing mode
Spacing mode can be used to verify the maximum acceptable spacing of receivers. Enable or
disable the spacing mode by setting switch number 1 on dip switch CFG2. Spacing mode is
disabled by default, where switch number 1 is set to the OFF position. To enable the spacing
mode, set switch number 1 on dip switch CFG2 to the ON position.