Robert Bosch Security Solutions Pte Ltd COR-RCV-433 Manuel D’Utilisation
24
en | Setting the Switches and Jumpers
Security Escort Coordinator & Receiver
2017.08 | SE3v1.0 | F.01U.277.701
Installation Manual
Robert Bosch (SEA) Pte Ltd
Reset Mode
Switch Number on Dip Switch CFG1
3
Soft reset (default setting)
OFF
Hard reset
ON
Tab. 5.7: Reset mode on dip switch CFG1
Pressing the Reset button on the coordinator/receiver performs the hard or soft reset
accordingly. The differences of the reset mode are described in Resetting the coordinator/
receiver, page 27.
accordingly. The differences of the reset mode are described in Resetting the coordinator/
receiver, page 27.
5.3
Setting the baud rate
Configure the baud rate of the RS-485 communication by using the dip switch CFG1. The
same baud rate must be set across the coordinator and the receivers in order for the RS-485
communication to work. Use the switch numbers 4 and 5 on dip switch CFG1 to set the baud
rate. The options are described in the following table.
same baud rate must be set across the coordinator and the receivers in order for the RS-485
communication to work. Use the switch numbers 4 and 5 on dip switch CFG1 to set the baud
rate. The options are described in the following table.
Baud Rate
Switch Number on Dip Switch CFG1
4
5
19200 (default setting)
OFF
OFF
38400
OFF
ON
57600
ON
OFF
115200
ON
ON
Tab. 5.8: Setting the baud rate on dip switch CFG1
5.4
Enable/disable the buzzer
Enable or disable the buzzer by setting the buzzer dip switch.
Set switch number 6 on dip switch CFG1 to the OFF position to disable the buzzer. Once
disabled, the buzzer will be muted at all times, including during alarm events.
Set switch number 6 on dip switch CFG1 to the ON position to enable the buzzer to be
operational. Once enabled, the buzzer will sound whenever triggered accordingly by the alarm
events.
Set switch number 6 on dip switch CFG1 to the OFF position to disable the buzzer. Once
disabled, the buzzer will be muted at all times, including during alarm events.
Set switch number 6 on dip switch CFG1 to the ON position to enable the buzzer to be
operational. Once enabled, the buzzer will sound whenever triggered accordingly by the alarm
events.
Enable/disable Buzzer
Switch Number on Dip Switch CFG1
6
Disable Buzzer (default setting)
OFF
Enable Operational Buzzer
ON
Tab. 5.9: Enable or disable the buzzer on dip switch CFG1
5.5
Enable/disable the spacing mode
Spacing mode can be used to verify the maximum acceptable spacing of receivers. Enable or
disable the spacing mode by setting switch number 1 on dip switch CFG2. Spacing mode is
disabled by default, where switch number 1 is set to the OFF position. To enable the spacing
mode, set switch number 1 on dip switch CFG2 to the ON position.
disable the spacing mode by setting switch number 1 on dip switch CFG2. Spacing mode is
disabled by default, where switch number 1 is set to the OFF position. To enable the spacing
mode, set switch number 1 on dip switch CFG2 to the ON position.