SHENZHEN ECARE ELECTRONICS CO. LTD 91505-1 Manuel D’Utilisation

Page de 6
 
The Daily Rainfall history bar chart is set as the default display after activation.   
 
To view the rainfall history for other time periods: 
  Press HISTORY once to display the weekly rainfall 
  Press again to display monthly 
  Press again to display last hour (will display for 5 seconds only) 
  Press again to display last 24 hours (will display for 5 seconds only) 
  Press again to return to daily 
 
The rainfall history bar chart displays in increments from 0.1” to 6.0”. Most of the time, the actual rainfall 
reading will fall between increments. The bar chart will show the last increment that was actually reached. 
For example: If the actual rainfall is 0.8”, the bar chart will show 0.5”. The chart will not show 1.0” until the 
actual rainfall total reaches 1.0”. 
 
More detailed daily, weekly and monthly history data are available. Press and hold the HISTORY button when 
your desire corresponding history data are shown. The “0” (Current) bar will show up and the precise data will 
be shown on the time display. Press + or – and you can scroll through the daily, weekly or monthly prior data. 
 
Note: On the bar chart display, the “0” represents the current period. -1, -2, etc. indicate the prior periods. 
 
MAXIMUM AND MINIMUM RECORDS 
 
Temperature Maximum and Minimum 
The highest and lowest record of indoor temperature, outdoor temperature and rainfall are stored automatically 
after you activate the base unit. You can recall the records at any time by pressing the MAX/MIN button. With 
each press of the button, in sequence the display will show; indoor maximum reached, indoor minimum reached, 
outdoor maximum, outdoor minimum, rainfall maximum and rainfall minimum. The corresponding MAX or 
MIN icon will be displayed each time. To clear any maximum or minimum record, press the CLEAR button 
when the appropriate record is shown on the display. 
 
Rainfall Maximum and Minimum   
The rainfall maximum and minimum record is a daily record which counts from 12:00am to 11:59pm every day.   
Aside from the automatic daily clear, the rainfall maximum or minimum record can be cleared by pressing the 
CLEAR button when the appropriate record is shown on the display. 
 
LOSING SYNCHRONIZATION 
If the main unit displayed a proper OUT temperature and rainfall rate, but now displays blanks “--.-C” or 
“--.—in”, the unit may have lost synchronization. If this occurs, press the RE-SYNC button of the main unit. 
The base unit will search for the RF (radio frequency) signal for 6 minutes and will re-initialize synchronization 
with the remote.