TEWS Elektronik GmbH & Co. KG MWT Manuel D’Utilisation
Technical Manual MW-T / Version: 1.6
2013-08-28
8.2. MW-T, Mounting View
9. Installation Advices
The MW-T is meant to be mounted on its rear panel. To this end, it is equipped with four mounting
brackets which each comprise a hole with a 10.5 mm diameter.
brackets which each comprise a hole with a 10.5 mm diameter.
In order to guarantee adequate cooling, all sides of the control cabinet must remain free, with the
exception of the rear panel. Especially, the distance of the heat exchanger installed on the left side
of the MW-T to walls or any other machine may not be less than 0.2 m (see figure in ch. 8.2).
exception of the rear panel. Especially, the distance of the heat exchanger installed on the left side
of the MW-T to walls or any other machine may not be less than 0.2 m (see figure in ch. 8.2).
The ventilation slots of the installed heat exchanger must not be closed up under any
circumstances.
circumstances.
On the bottom side of the MW-T, there are connectors for the connection of external components
such as antennas, light barriers etc. Here, adequate space for the cables must be provided. Wiring
must be arranged.
such as antennas, light barriers etc. Here, adequate space for the cables must be provided. Wiring
must be arranged.
In order to ensure a high level of accuracy of the MW-T measuring system, the installation of the
antennas must be given special attention:
antennas must be given special attention:
●
The antennas should be placed centric to the measurement object.
●
Behind or next to the antennas a space of at least 0.5m must be maintained free from objects
and people (see following figure).
and people (see following figure).