S.R. Smith LLC WPCPT6WIR Manuel D’Utilisation

Page de 16
 
79-15053-00 REV. D4 
www.srsmith.com
  
Page 3 of 16 
 
Basic safety precautions should be observed when operating the WPC-1 product and other 
associated equipment. 
 
1.  A qualified electrician must install the WPC-1 in accordance to the National and Local 
Electrical Codes. 
2.  The WPC-1 must not be less then 5 feet (3 meters in Canada) from inside edge of pool.  
ONLY USE COPPER CONDUCTORS. 
3.  Do not exceed the maximum ratings of individual components, wiring devices, and current 
carrying capacity of conductors. 
4.  For the bonding, grounding, installing, and wiring of underwater lights to the WPC-1, refer 
to Article 680 of the National Electrical Code or Article 68 of the Canadian Electrical Code. 
5.  This device should never operate equipment that could cause property damage, bodily 
injury, or death should it be activated unexpectedly. 
6.  Never allow children to operate the WPC-1 unsupervised.
IMPORTANT SAFETY INFORMATION 
ELECTRICAL RATINGS 
Do not exceed the maximum electrical ratings of the WPC-1.  A circuit breaker rated at 20Amps
at 120VAC must be installed in the breaker panel to connect to the WPC-1 power input.  Circuit
1 and Circuit 2 are each rated for use of up to 8Amps @ 120VAC.  The Pump Relay is rated at a
maximum of 3HP @ 240VAC. 
SAVE THESE INSTRUCTIONS!
 
1.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following 
two conditions: (1) this device may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that may cause undesired operation. 
2.  Changes or modifications not expressly approved by SR Smith, LLC. could void the user's 
authority to operate the equipment.
FCC WARNING