Elkay Manufacturing Co. NFC1 Manuel D’Utilisation

Page de 21
C L
C L
FI
NI
SHE
D F
LO
OR
15
"
38
1m
m
7/
8"
73
m
m
34
 5
/1
6"
87
1m
m
19
 7
/1
6"
49
4m
m
2" 51
m
m
3/
4"
14
6m
m
7" 17
8m
m
7" 17
8m
m
22
 1
5/
16
"
58
3m
m
24
 1
/2
"
62
2m
m
28
 1
3/
16
"
73
2m
m
3/
8"
16
2m
m
3/
8"
16
2m
m
7" 17
8m
m
7" 17
8m
m
18
"
45
8m
m
12
 1
/2
"
31
8m
m
27
"
68
6m
m
AD
A
RE
Q
UI
RE
M
EN
T
31
 5
/1
6"
79
6m
m
RI
M
HE
IG
HT
32
 7
/8
"
83
5m
m
O
RI
FI
CE
HE
IG
HT
1/
2"
90
m
m
A PR
EF
ER
RE
D
LO
CA
TI
O
N
B
D
AL
TE
RN
AT
E
LO
CA
TI
O
N
1/
16
"
20
5m
m
HA
NG
ER
BR
AC
KE
T
38
 3
/8
"
97
5m
m
O
RI
FI
CE
HE
IG
HT
E
F
F
13
 1
5/
16
"
35
4m
m
17
 7
/1
6"
44
3m
m
19
"
48
3m
m
2" 51
m
m
7/
8"
22
m
m
18
 3
/8
"
46
7m
m
3/
8"
16
2m
m
3/
8"
16
2m
m
A AL
TE
RN
AT
E
LO
CA
TI
O
N
E
FI
LT
ER
38 9/
16"
979
m
m
AC
TI
VA
TI
O
N
SE
NSO
R
1 7/
8"
48m
m
3" 76m
m
2" 51m
m
O
 9/
32"
 (7m
m
)
HO
LE
S (
12)
3 7/
8"
98m
m
21 7/
8"
556
m
m
51 5/
8"
131
1m
m
7/
16
" X
 3
/4
" (
11
m
m
 X
 1
9m
m
)
O
BR
O
UN
HO
LE
(6
)
19" 483
m
m
36 13/
16"
936
m
m
RI
M
HE
IG
HT
LEGEND
/LEYENDA
/LÉGENDE
RECOMMENDED
 W
ATER
 SUPPL
LOCA
TION
 3
/8
 O
.D
. UNPLA
TED
 COPPER
 TUBE
 CONNECT
 STUB
 WITH
 SHUT
 OFF
 (BY
 OTHERS
) 3
 IN
(76
mm
) MAXIMUM
 OUT
 FROM
 W
ALL
 
UBICACIÓN
 RECOMENDADA
 DEL
 SUMINISTRO
 DE
 AGUA
. TUBERÍA
 DE
 COBRE
 SIN
 REVESTIMIENT
O
 DE
 3
/8
" DE
 DIÁM
. EXT
. ADAPT
ADOR
 
DE
 CONEXIÓN
 CON
 VÁL
VULA
 DE
 CIERRE
 (DE
 TERCEROS
) MÁXIMO
 A
 7
mm
 (3
")
 DE
 LA
 P
ARED
.
 
EMPLACEMENT
 RECOMMANDÉ
 DE
 L
’ARRIVÉE
 D
’EAU
. TUBE
 EN
 CUIVRE
 NON
 PLAQUÉ
 DE
 3
/8
 PO
 DE
 DIA
. EXT
. RACCORDER
 À
 LA
 
CONDUITE
 D
’ALIMENT
ATION
 A
VEC
 UN
 ROBINET
 D
’ARRÊT
 (NON
 FOURNI
) À
 7
mm
 (3
 PO
) MAXIMUM
 DU
 MUR
B
 =
 RECOMMENDED
 LOCA
TION
 FOR
 W
ASTE
 OUTLET
 1
-1
/2
O
.D
. DRAIN
 STUB
 2
 IN
. OUT
 FROM
 W
ALL
 
UBICACIÓN
 RECOMENDADA
 DE
 LA
 SALIDA
 DE
 DESECHOS
. ADAPT
ADOR
 DE
 DESAGÜE
 DE
 1
-1
/2
" DE
 DIÁM
. EXT
., 
51
 mm
 (2
")
 DE
 LA
 
PARED
.
 
EMPLACEMENT
 RECOMMANDÉ
 DE
 LA
 SOR
TIE
 D
’ÉCOULEMENT
. CONDUITE
 D
’ÉV
ACUA
TION
 DE
 1
-1
/2
 PO
 DE
 DIA
. EXT
. DÉP
ASSANT
 DE
 
51
 mm
 (2
 PO
) HORS
 DU
 MUR
C
 =
 1
-1
/2
TRAP
 NOT
 FURNISHED
 
NO
 SE
 INCLUYE
 SIFÓN
 DE
 1
-1
/2
"
 
SIPHON
 DE
 1
-1
/2
 PO
 NON
 FOURNI
LEGEND
/LEYENDA
/LÉGENDE
D
 =
 ELECTRICAL
 SUPPL
(3
) WIRE
 RECESSED
 BOX
 DUPLEX
 OUTLET
**
SUMINISTRO
 ELÉCTRICO
 (3
) CAJA
 ENCHUFE
 DE
 ALAMBRE
 SALIDA
 DÚPLEX
ALIMENT
ATION
 ÉLECTRIQUE
 (3
) BOÎTIER
 ENCASTRÉ
INSURE
 PROPER
 VENTILA
TION
 BY
 MAINT
AINING
 6
(1
52
 mm
) (
MIN
.) 
CLEARANCE
 FROM
 CABINET
 LOUVERS
 T
O
 W
ALL
.
 
PARA
 GARANTIZAR
 LA
 VENTILACIÓN
 ADECUADA
, MANTENGA
 1
52
 mm
 (6
")
 (MÍN
.) 
DE
 SEP
ARACIÓN
 DESDE
 LAS
 REJILLAS
 DEL
 
GABINETE
 HAST
LA
 P
ARED
.
 
POUR
 ASSURER
 UNE
 AÉRA
TION
 SUFFISANTE
, PRÉVOIR
 UN
 DÉGAGEMENT
 DE
 1
52
 mm
 (6
 PO
) (
MIN
.) 
ENTRE
 LES
 ÉVENTS
 DE
 
L’
ENCEINTE
 ET
 LE
 MUR
.
7/
16
 BOL
HOLES
 FOR
 F
ASTENING
 UNIT
 T
O
 W
ALL
 
ORIFICIOS
 P
ARA
 PERNOS
 DE
 7
/1
6,
 P
ARA
 FIJAR
 LA
 UNIDAD
 A
 LA
 P
ARED
 
TROUS
 DE
 VIS
 DE
 7
/1
PO
 POUR
 LA
 FIXA
TION
 DE
 L
’APP
AREIL
 AU
 MUR
**
NEW
 INST
ALLA
TIONS
 MUST
 USE
 GROUND
 F
AUL
CIRCUIT
 INTERRUPTER
 (GFCI
)
**Les nouvelles installations doivent comporter un disjoncteur différentiel (
GFCI
)
**
Les nouvelles installations doivent employer l’interrupteur de circuit moulu de défaut (GFCI)
AL
TERNA
TE ROUGH-IN FOR RIGHT
-HAND HIGH, BOTTLE FILLER LOW MODELS – REQUIRES BASIN 
ASSY
 CHANGE
BOSQUEJO
 AL
TERNA
TIVO
 P
ARA
 MODELOS
 CON
 LA
 LLENADORA
 DE
 BOTELLAS
 BAJA
 Y
 LA
 P
AR
TE
 DERECHA
 AL
TA
: REQUIERE
 CAMBIAR
 EL
 CONJUNT
O
 DE
 T
ARJA
AUTRE DISPOSITION DE CANALISA
TIONS, POUR INST
ALLA
TION DROITE HAUTE ET
 REMPLISSEUSE DE BOUTEILLE BASSE – MODIFICA
TION DE LA
 FONT
AINE REQUISE
FIG. 2
REDUCE HEIGHT BY
 3 INCHES FOR INST
ALLA
TION OF CHILDREN’S 
ADA
 COOLER
Reduzca la altura en 76 mm (3") para la instalación del bebedero con clasificación 
ADA
 para niños
Réduire la hauteur de 76
 mm (3
 po) pour les installations à la norme 
ADA
 enfants
Page 3
1000004543  (Rev. A - 10/18)
ENLZSTL8WS_1G