REMOTE SERIAL OPERATION OVER RS232
When the Well Watch display is connected to a computer or other bi-directional  remote 
device, the display unit can be controlled and configured using a set of simple 
commands. 
If using a terminal emulator on the computer, establish a connection between the 
computer and the display selecting the COM port connected to the display. If your 
computer has a built-in com port, it will probably be COM1. If you are using a USB 
adapter it may be any where from COM3 thru COM12. Then enter the port settings: 
19200 baud, 8 data bits, parity none, 1 stop bit, and flow control none. Turn on the Well 
Watch display and press the <return> key on your computer. If it is set up correctly, the 
display will return with a line of data  and a WS310> prompt on the screen.  If the Well 
Watch display does not respond, select a different COM port and try again. 
Once the connection has been established, commands can be send from the computer 
to the Well Watch. The remote commands are case sensitive and must be entered 
exactly as shown on the list below.  One command per line, terminated by a <return>. 
Extra tabs or spaces will not be accepted. 
Examples:
Press "s1<return>" to enable continuous transmission of data on the RS232 port. 
Press "u0<return>" to set english units mode or "u2<return>" to set metric.
If serial output is enabled, the prompt and input may be written over on the screen but 
the input will still be interpreted correctly. It may be easier to disable the serial output 
while using remote commands. Press “s0<return>” to turn off serial reporting and 
“s1<return>” to turn in back on when finished.
USER REMOTE COMMANDS -  In the following list, [iiii] indicates a parameter of up to 
a 4 character integer (no decimal point), [ddddd] indicates up to 5 character decimal 
number (decimal point optional), [cc] indicates two nonnumeric characters, and  <ret> 
indicates a return.
<ret>
send current data
a0<ret>
alarm off
a1<ret>  
low alarm on
a2<ret>
high alarm on
  Eno Scientific  Well Watch 310