Dolby Laboratories ACCESSLINK Manuel D’Utilisation

Page de 62
FAL.OM.002372.DRM 
Page 38 of 62 
Version 1.6 
 
Doremi Labs 
5   CaptiView Configuration 
The AccessLink device enables customers who do not have a Doremi Digital Cinema  
Server to use the CaptiView device using SMPTE ST 430-10 and ST 430-11 
protocol from a non-Doremi Digital Cinema server. There are three ways to set up the 
AccessLink's CaptiView network: First, the USB method is the primary way to set up the 
network of the device; second is the Ethernet Port; and the third method is to use the Serial 
Port. Logging in using SSH or serial connection is required to complete the setup of the device. 
5.1   Items to Configure 
All the items mentioned below must be configured for a CaptiView to work properly on an 
AccessLink (Figure 39, Figure 40, and Figure 41)
  Network configuration: 
◦  IP address 
◦  Netmask 
◦  Gateway 
  Auditorium number: Each auditorium in the theater must have its own auditorium number 
assigned to the CaptiView Transmitter Dongle. 
  Server's IP address: The IP address of the server that is going to be used with the 
AccessLink must be added to the AccessLink's configuration. 
 
Figure 39: AccessLink 
Note: The CaptiView transmitter (if connected to the AccessLink) shall at least be 20cm away 
from the AccessLink antenna 
– usage of a USB extension cable is needed for the CaptiView 
transmitter connection. 
CaptiView 
Transmitter 
Port