Baicells Technologies Co. Ltd. CW0100 Manuel D’Utilisation

Page de 23
 
16 
 
4. Power on Detection 
  Detection Item 
4.1
Power on detection includes the following four items: 
 
Ethernet port working status 
 
CPE configuration check 
 
CPE access test 
 
CPE parameter record 
  Ethernet Port Working Status 
4.2
After  CPE  powered  on,  waiting  for  2  minutes,  connect  the  Ethernet  port  of  PC  to  POE 
adaptor. 
The  CW0100  CPE  default  IP  address  is  192.168.1.1.  Set  the  IP  address  of  PC  is 
192.168.1.2, ensure that the Ethernet indicator get light and ping CPE IP address normal. 
  CPE Configuration Check 
4.3
Log in the WebUI of CPE, check whether the software version is correct, whether the LTE 
mode is enabled, and whether WAN interface and LAN interface are consistent with plan. 
  CPE Access Test 
4.4
Insert into USIM card, set the WAN interface to LTE mode, set LTE to auto connection, 
check terminal connection status, and check whether the terminal can san LTE signal and 
get IP address. After the connection is established, service testing can be made, such as 
HTTP, FTP, and so on. 
  CPE Parameter Record 
4.5
Record parameter of CPE, such as installation site, installation height, antenna direction 
angle, and so on.