Baicells Technologies Co. Ltd. CW0100 Manuel D’Utilisation

Page de 23
 
15 
 
Figure 3-13 POE power Mode 
 
 
  Lightning Protection of Cable 
3.4
It need to use shielded cable and ensure the grounding of two ends of equipment. If the 
opposite  equipment  has  plastic  enclosure,  which  cannot  be  grounding.  In  this  situation, 
the shielded cable function is decreased largely.   
If its available, it is recommended that Ethernet cable and power cable pass through metal 
sleeve to ground separately. And they cannot be in a same metal sleeve. 
It  is  highly  recommended  that  the  distance  is  as  nearest  as  possible  between  the  two 
equipment connected by Ethernet cable, avoiding the cable hanging in the air. According 
to  the  wiring  environment,  the  lightning  protection  demand  is  different,  the  details  is 
described in Table 3-1. 
Table 3-1 Lightning Protection Demand of Cable 
Number 
Environment 
Lightning Protection 
Demand 
Completely in indoor or underground 
No special demand 
Outdoor part exceed 3m 
4KV(10/700us) 
Outdoor part exceed 10m 
3KA 
Outdoor part exceed 10m, and application 
environment is poor, such as the cable hanging 
in the air, strong lightning area, and so on. 
5KA