5.1.1  Step 1/3: Measuring the inside diameter DI using the gauge  
 
 
 
 
Tighten  the  diameter  gauge, 
taking care to align the handle 
with the pipe axis. 
1. Open the insert valve and lower 
the gauge until it stops against the 
bottom of the pipe. 
2.  Lower  the  two  identification 
rings  onto  the  gauge  watertight 
fitting. 
3. Lock Ring A in this position using 
the knurled screw. 
1. Rotate the gauge through 180°. 
2.  Bring  the  gauge  back  up  until  it  stops  against 
the upper surface of the pipe. 
3.  Position  Ring  B  where  it  stops  against  the 
watertight  fitting  of  the  gauge.  Secure  Ring  B  in 
this position using the knurled screw 
Measure  the  inside  diameter 
DI between the external faces 
of the two rings. 
It might not be possible to measure the DI (lack of space in the port or diameter too large). In that case, replace the DI value with an 
estimate (e.g., manufacturer data). 
DI 