Riello Sentinel Power 6000 SPW 6000 Manuel D’Utilisation
Codes de produits
SPW 6000
www.riello-ups.com
High UPS reliability
• Total microprocessor control
• Static and manual bypass without
• Total microprocessor control
• Static and manual bypass without
interruption
• Features guaranteed up to 40° C (the
components are designed to work at
high temperatures and thus are subject
to less stress at normal temperatures)
high temperatures and thus are subject
to less stress at normal temperatures)
Operation selection
The operating mode may be programmed
using software or manually via the mimic
panel.
• On-line
• ECO Mode, to increase output (up to
The operating mode may be programmed
using software or manually via the mimic
panel.
• On-line
• ECO Mode, to increase output (up to
to 98%), allows for selection of Line
Interactive technology (VI) to power low
priority loads from the mains supply.
Interactive technology (VI) to power low
priority loads from the mains supply.
• Smart Active, the UPS automatically
decides upon the operating mode
(VI or VFI) based on the quality of the
network.
(VI or VFI) based on the quality of the
network.
• Back-up, the UPS can be selected to
function only when mains power fails
(emergency mode only)
(emergency mode only)
• Frequency converter (50 or 60 Hz).
High quality output voltage
• Even with non-linear loads
(loads with a crest factor of up to 3:1)
• High short circuit current on Bypass
• High overload capacity 150% by
• Even with non-linear loads
(loads with a crest factor of up to 3:1)
• High short circuit current on Bypass
• High overload capacity 150% by
inverter (even with mains failure).
• Filtered, stabilised and reliable voltage
(double conversion On-line technology
(VFI compliant with IEC 62040-3)
with filters for the suppression of
atmospheric disturbances.
(VFI compliant with IEC 62040-3)
with filters for the suppression of
atmospheric disturbances.
• Power factor correction: UPS input
power factor, close to 1 and sinewave
current absorption
current absorption
Simplified Installation
• UPS can be installed on single-phase or
• UPS can be installed on single-phase or
three-phase distribution network
• Output terminal board + 2 IEC sockets
for powering local utilities (computers,
modems, etc.)
modems, etc.)
• Simplified positioning (built-in wheels).
High battery reliability
• Automatic and manual battery test
• Reduced ripple component (detrimental
• Automatic and manual battery test
• Reduced ripple component (detrimental
to the batteries) thanks to the “LRCD”
system (Low Ripple Current Discharge)
system (Low Ripple Current Discharge)
• Unlimited extendible runtime via
dedicated modular design Battery
Boxes
Boxes
• The batteries are not activated during
mains failure of <40 ms (high hold up
time) or when there are variations in
input voltage (from 84V to 276V).
time) or when there are variations in
input voltage (from 84V to 276V).
EnergyShare
The presence of two 10A configurable
IEC output sockets, allows for runtime
optimisation, programming the switch-
off of low priority loads; alternatively,
emergency only loads, normally not
powered when the mains is present, can
be activated.
The presence of two 10A configurable
IEC output sockets, allows for runtime
optimisation, programming the switch-
off of low priority loads; alternatively,
emergency only loads, normally not
powered when the mains is present, can
be activated.
Low impact on mains network
• Sinusoidal absorption of input current
• Sinusoidal absorption of input current
on single-phase/single-phase series.
Other features
• Advanced diagnostics: status,
• Advanced diagnostics: status,
measurements, alarms available on
custom LDC display
custom LDC display
• Low noise (<40dBA) for installation
in any environment thanks to PWM
digitally-controlled ventilation,
depending on the load applied and on
the use of a high frequency switching
inverter (>20kHz, value greater than the
audible range)
digitally-controlled ventilation,
depending on the load applied and on
the use of a high frequency switching
inverter (>20kHz, value greater than the
audible range)
• Auto restart (automatic when mains
supply is restored, programmable via
software or mimic panel)
software or mimic panel)
• Emergency back-up function, the UPS
can be selected to function only when
mains power fails (emergency lighting
only)
mains power fails (emergency lighting
only)
• Back feed protection standard: to
prevent energy from being feed back
into the main supply
into the main supply
• UPS digital updating (flash upgradable)
Advanced communication
• Compatible with Riello UPS
• Compatible with Riello UPS
TeleNetGuard teleassistance
• Advanced multi-platform
communication for all operating
systems and network environments:
PowerShield
systems and network environments:
PowerShield
3
supervision and
shutdown software for Windows
operating systems 7, 2003, Vista, 2003,
XP, Linux, Mac OS X, Sun Solaris,
Linux, Novell and other Unix operating
systems.
operating systems 7, 2003, Vista, 2003,
XP, Linux, Mac OS X, Sun Solaris,
Linux, Novell and other Unix operating
systems.
• RS232 serial port
• Plug and Play function
• Slot for installation of communications
• Plug and Play function
• Slot for installation of communications
boards.