Data Field Descriptions 
 
35
 
Entry Delay 01 
00-99 = entry delay time in seconds.
 
The system will wait the time entered before sounding alarm upon entering 
if system is not disarmed. UL installations: must be set for a maximum of 
45 seconds 
 
36
 
Entry Delay 02 
00-99 = entry delay time in seconds.
 
The system will wait the time entered before sounding alarm upon 
entering. UL installations: must be set for a maximum of 45 seconds 
 
37
 
Audible Exit Warning/Quick Exit 
 
Exit Warning 
Quick Exit 
0 = no exit warning 
sound 
0 = no quick 
exit 
1 =  provide exit 
warning sound 
when armed AWAY 
1 = allow quick 
exit 
  
Exit Warning: Sound consists of slow continuous beeps until last 5 seconds, 
when it changes to fast beeps. The warning sound will end at the 
termination of exit delay.  
 
Quick Exit: If enabled, user can restart the exit delay time after arming in 
STAY mode by entering the user code and pressing the STAY key, or by 
pressing the STAY key if Quick Arm is enabled. This avoids having the 
user disarm then re-arm the system after allowing someone to enter or exit 
 
38
 
Confirmation of Arming Ding 
0 = no ding 
1 = confirmation ding after arming system 
2 = confirmation ding after arming from RF button or 
RF keypad only 
 
Confirmation of arming is provided by a 1/2 second external sounder “ding” 
that sounds when closing report is sent, or at the end of exit delay. 
 
If Option 2 is selected the external sounder “ding” occurs immediately after 
the system receives the RF transmission. 
39
 
Power Up In Previous State 
0 = always power up in a disarmed state 
1 = assume the system status prior to power-down
 
When the system powers up armed, an alarm will occur 1 minute after 
arming if a zone is faulted, and any bypassed zones will be unbypassed. 
Note: If the previous state was armed AWAY or STAY, the system will not 
respond to sensor changes for 1 minute, which allows time for sensors such 
as PIRs to stabilize. UL installations: must be 1 (power up in previous 
state) 
 
 
DIALER PROGRAMMING (
40–
50)
 
 
Fields 
 ✻
40, 
41, 
42: Enter up to the number of digits shown. Enter 0–9, # + 11 for ‘*’; # + 12 for ‘#’; # + 13 for a pause 
(2 seconds) 
NOTE:  Whenever AAV is used, primary (field 
✻41) and secondary (field ✻42) phone numbers should be preceded with the call waiting 
disable command.  Otherwise, there is the possibility of connection of the third party to LYNX during AAV mode. 
 
40
 
PABX Access Code 
Enter up to 6 digits if PABX is needed to access an 
outside line. 
 
If fewer than 6 digits need to be entered, exit by pressing [
].  To clear 
entries from field, press 
40
41
 
Primary Phone No.  
Enter up to 20 digits. 
 
If fewer than 20 digits entered, exit by pressing [
].  To clear entries from 
field, press 
41
Note: Backup reporting (8 attempts are made to the secondary phone 
number if no kissoff is received after 8 attempts to the primary 
number) is automatic only if there is a secondary phone number 
(field 
42). 
 
 
42
 
Secondary Phone No.  
Enter up to 24 digits. 
 
If fewer than 24 digits entered, exit by pressing [
].  To clear entries from 
field, press 
42
.  See backup reporting note for field 
41. If using the 
paging feature, enter the pager phone number here. 
 
!
 
All four digits of the Subscriber Account number must be entered in Fields 43 and 44. If ten digit format is 
selected in 
48 (option 5), all ten digits of the Subscriber Account number must be entered. 
Fields 
43 and 
44: 
Enter [
]  as the fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as the first 
digit of a 4-digit account number for Nos. 0000–0999.  Enter [
] as the fifth digit if a 4-digit account number (for 3+1, 
CID®) is used. Exit field by pressing [
] if only 3 digits are used. To clear entries from field, press 
43
 or 
44
. See 
blank Programming Form for examples of account number entries. If using the paging feature, do not enter a leading 0 
in the subscriber account number, and do not use digits A-F anywhere in the number. Some paging systems provide 
voice mail capability, which is activated by a leading 0 in the message. Enter digits 0–9; # +11=B; # +12=C; # +13=D; # 
+14=E; or # +15=F. 
 
43
 
Primary Subs Account No.  
Enter a four or ten digit account number. 
 
Enter the primary subscriber account number. 
To clear entries from field, press 
43
44
 
Secondary Subs Account No.  
Enter a four or ten digit account number. 
 
Enter the secondary subscriber account number. 
To clear entries from field, press 
44