Honeywell ADEMCO LYNXR Series Manuel D’Utilisation

Page de 72
 
–19– 
Data Field Descriptions 
 
Field 46: Enter up to 24 digits. Do not fill unused spaces. Enter 0-9, #+11 for ‘*’; #+12 for’#’; #+13 for a pause (2 seconds).     
46 
“Follow Me Reminder” Phone Number 
Enter up to 24 digits. 
This option allows the user to schedule a time driven message. When 
activated the system will dial the phone number programmed and deliver a 
voice message (custom words 72, 73 and 74). This option is only supported 
when the pager or follow me feature is enabled in field 
49 (option 6-9 or 
10-13). 
If using the Follow Me Reminder feature, enter the phone number here. If 
fewer than 24 digits are entered, exit by pressing [
]. To clear entries from 
the field press 
46
. 
The telephone message can be terminated (acknowledged) by pressing any 
key on the telephone keypad.  Pressing any key on the local LYNXR keypad 
will terminate (acknowledge) both the follow me and the local reminder 
announcements.  
Note:  The follow me reminder announcement will be terminated if any 
other event requires the system to dial out or if and audible alarm 
has occurred. 
47
 
Phone System Select 
Note:  For LYNXR/LYNXR24 only options 0, 1, 2, and 3 
are applicable. For LYNXR-EN all options apply. 
 
Central 
 
Dialing Mode 
 
Station Pulse Tone Pulse Tone 
No WATS 
0 = No 
Speaker 
Phone 
1 = No 
Speaker 
Phone 
 4 = With 
Speaker 
Phone 
5 = With 
Speaker 
Phone 
WATS 
2 = No 
Speaker 
Phone 
3 = No 
Speaker 
Phone 
6 = With 
Speaker 
Phone 
7 = With 
Speaker 
Phone 
 
 
 
 
 
 
This option is used to enter the correct type of phone dialing (pulse or tone), 
and to select the correct WATS line option for the Central Station. For 
LYNXR-EN this option is used to activate the speaker phone option. 
 
Note: If using pulse dialing, you must enter the numbers slowly in order to 
allow the pulse dialer time to operate. 
48
 
Report Format for Primary/Secondary 
 
Primary Secondary 
See choices below 
See choices below 
0 = 3+1; 4+1 ADEMCO Low Speed Standard 
1 = 3+1; 4+1 Radionics Standard 
2 = 4+2 ADEMCO Low Speed Standard 
3 = 4+2 Radionics Standard 
5 = ADEMCO Contact ID® Reporting with 10-digit 
subscriber account number 
6 = 4+2 ADEMCO Express 
7 = ADEMCO Contact ID® Reporting with 7-digit 
subscriber account number 
8 = 3+1; 4+1 ADEMCO Low Speed Expanded 
9 = 3+1; 4+1 Radionics Expanded 
 
Enter 
 as the 4th digit of 
43 through 
44, if 3+1 dialer reporting is to be 
used. (For an explanation of these formats, see the System Communication 
section of  this manual.) 
Notes:  (1)  The maximum number of alarm and alarm restore reports 
during one armed period is determined by field 
92. 
 
(2)  If Option 5 is selected a 10-digit account number must be 
entered in Fields 
43 or 
44. 
 
(3)  Option 5 or 7  (ADEMCO Contact ID® Reporting) must be 
selected for AVM. 
 
(4)  Option 5 or 7  (ADEMCO Contact ID® Reporting) must be 
selected if installing the 5842 Wireless Dialer. 
 
 
 
49 
Split/Dual Reporting 
 
 
To Primary 
To Secondary 
0 = All reports 
None, unless primary 
 
 
 fails, then all 
1 = Alarms, Restore, Cancel 
Others 
2 = All except Open/Close, Test 
Open/Close, Test 
3 = Alarms, Restore, Cancel 
All 
4 = All except Open/Close, Test 
All 
5 = All reports 
All 
 
To Primary 
To Paging Number 
6 = All reports except Open/Close 
Alarms, Open/Close ‡,  
  
Troubles 
7 = All reports 
Alarms, Troubles 
8 = All reports 
Alarms, Open/Close ‡,  
  
Troubles 
9 = All reports except Open/Close 
Open/Close ‡ 
 
 
To Primary 
To Follow Me System  
  
Phone 
Number 
10=All reports except Open/Close 
Alarms, Open/Close ‡,  
  
Troubles 
11 = All reports 
Alarms, Troubles 
12=All reports 
Alarms, Open/Close ‡,  
  
Troubles 
13=All reports except Open/Close 
Open/Close ‡ 
‡ Will report Users 0, 5-8, and, if using wireless button-type 
devices, will report the zone number of the arm or disarm 
button 26-33. All other zones and users are not reported.
 
This field is used to select a reporting option as follows: 
Enter:  0 - 5 when reporting to telephone receivers. 
 
6 - 9 when reporting to a pager is desired. 
 
10 - 13 when reporting to an auxiliary telephone receiver. 
 
Pager Report Format 
Options 6-9 send reports to the primary phone number, in a format defined 
in Field 
48, and send reports to a pager, which has its phone number 
entered as the secondary phone number in Field 
42.  The pager report is a 
7-digit code, with optional 16-digit prefix, in the following format:  
AAAAAAAAAAAAAAAA-EEE–00NN  where: 
AAA =  Optional 16 digits for PIN number, etc. See Field 
88 for full 
description of these characters. 
EEE =  3-digit Event Code as follows: 
911 =   Alarm (NN = zone number) 
101 =   Open, system disarmed (NN = user no.) 
102 =   Close, system armed (NN = user no.) 
811 =    Trouble (NN = zone no.) 
00  = 
Always displayed before 2-digit user/zone no. 
NN = 
2-digit user number or zone number, depending on the type of 
event (EEE) that occurred. NN=00 indicates AC loss, system low 
battery, or low battery in 5827. 
 
Follow Me System Report Format 
Options 10-13 send reports to the primary phone number, in a format 
defined in Field 
48, and sends voice message to the secondary phone 
number entered in Field 
42. 
The message is a repeatable system status announcement. If the manual 
paging option has been programmed in Field 
87, the message will repeat 
“system, system…..”. 
 
The message can be terminated by pressing any key on the telephone 
keypad. 
 
Get user manuals: 
See SafeManuals.com