Conrad Energy 9 V / PP3 battery (rechargeable) NiMH NIMH 9V BLOCK 200 mAh 8.4 V 1 pc(s) 251055 Fiche De Données
![Conrad Energy](https://files.manualsbrain.com/attachments/be9b10a74b96bbc651886ed3b9892a77e7fe3f43/common/fit/150/50/1840239b5a299ff762cfbdd227cfce01ee36fbf269d67534cfc59a89d230/brand_logo.gif)
Codes de produits
251055
Document Number:LHB-x Vision: A Page
4
of 7
Test Items
Test Conditions
Requirements
Remark
Drop resistance
Charge the battery at 0.1It for 15hours.
Then leave for 24 hours, check battery
before
Then leave for 24 hours, check battery
before
/ after dropped.
Height: 100 cm
Thickness of the wooden board : 30 mm
Thickness of the wooden board : 30 mm
Change of voltage
Δ
V<0.02V/ cell
Change of internal impedance
Δ
R<5mΩ/ cell
No breakage except impact
point for PVC sleeves
point for PVC sleeves
Direction is not specified,
Test for 3 times
Test for 3 times
Safety
The Reverse-charge is conducted for 60
minutes at current of 1.0It after
pre-discharge at 0.2 It current to 0V
minutes at current of 1.0It after
pre-discharge at 0.2 It current to 0V
The battery shall not explode,
but leakage & deformation are
acceptable
but leakage & deformation are
acceptable
External Short
Circuit
After standard charge, short circuit
the cell at 20+/-5℃ until the cell
temperature returns to ambient
temperature. (The resistance of the
inter-connecting circuitry shall not
exceed 0.1ohm.)
The battery shall not fire and
explode, but leakage &
deformation are acceptable
External Short Circuit
★ If the ambient temperature is changed,the date may be different from the above value.
*REMARK:
1. Cycle life: IEC61951-2(2003) 7.4.1.1
Cycles Charge rest Discharge
1 0.1I
B
t
B
×
16hrs 0
0.25
I
B
t
B
×
2hrs 20mins
2~48 0.25
I
B
t
B
×
3hrs 10mins
0
0.25 I
B
t
B
×
2hrs 20mins
49 0.25
I
B
t
B
×
3hrs 10mins
0
0.25 I
B
t
B
to 1.0V/cell
50 0.1
I
B
t
B
×
16hrs 1~4hrs
0.20
I
B
t
B
to 1.0V/cell
Repeat 1 to 50 cycles, until the discharge time of any 50
P
th
P
cycle is less than 3hrs
2. COSMETIC
Batteries should be without any flaw、stain、discoloration or leakage and deformation.
3. CAUTION:
3.1 Do not dispose of cell into fire or dismantled under any condition.
3.2 Do not mix different cell types and capacities in the same battery assembly.
3.3 Charge and discharge under specified ambient temperature
3.2 Do not mix different cell types and capacities in the same battery assembly.
3.3 Charge and discharge under specified ambient temperature
.
3.4
3.5 Never solder onto cell directly.
3.5 Never solder onto cell directly.
Short circuit leading to cell venting must be avoided.
3.6 Cell reversal should be avoided.
4. NOTICE:
4.1 Use batteries in extreme condition may affect the service life, such as: extreme temperature 、deep cycle、extreme
overcharge and over discharge.