Rigol MSO1074Z-S 4-channel oscilloscope, Digital Storage oscilloscope, MSO1074Z-S Manuel D’Utilisation
Codes de produits
MSO1074Z-S
RIGOL
DS1000Z Programming Guide
2-101
:TRIGger:DURATion:WHEN
Syntax
:TRIGger:DURATion:WHEN <when>
:TRIGger:DURATion:WHEN?
:TRIGger:DURATion:WHEN?
Description
Set or query the trigger condition in duration trigger.
Parameter
Name
Type
Range
Default
<when> Discrete
{GREater|LESS|GLESs}
GREater
Explanation
). The
oscilloscope triggers when the duration of the pattern is greater than the preset time.
). The
oscilloscope triggers when the duration of the pattern is lower than the preset time.
GLESs: you need to specify a upper limit of time (refer
) and lower limit of time (refer
). The oscilloscope triggers when the duration of the
pattern is lower than the preset upper limit of time and greater than the preset lower
limit of time.
Return
Format
The query returns GRE, LESS or GLES.
Example
:TRIGger:DURATion:WHEN LESS
Related
Command
:TRIGger:DURATion:TUPPer
Syntax
:TRIGger:DURATion:TUPPer <NR3>
:TRIGger:DURATion:TUPPer?
:TRIGger:DURATion:TUPPer?
Description
Set or query the duration time upper limit in duration trigger. The default unit is s.
Parameter
Name
Type
Range
Default
<NR3>
Real
Related to the trigger condition
LESS: 8ns to 10s
GLESs: 16ns to 10s
2μs
Explanation
This command is available when the trigger condition (
) is
LESS or GLESs.
Return
Format
The query returns the duration time upper limit in scientific notation.
Example
:TRIGger:DURATion:TUPPer 0.000003 /*Set the duration time upper limit to 3μs*/
:TRIGger:DURATion:TUPPer? /*The query returns 3.000000e-06*/
Related