DS1000Z Programming Guide
2-77
:SYSTem:ERRor[:NEXT]?
Syntax
:SYSTem:ERRor[:NEXT]?
Description
Query and delete the last system error message.
Return
Format
The query returns the error message in “<message number>,<message content>”
format. Wherein, the message number is an integer and the message content is a ASCII
character string. For example, -113,"Undefined header; command cannot be found".
:SYSTem:GPIB
Syntax
:SYSTem:GPIB <adr>
:SYSTem:GPIB?
:SYSTem:GPIB?
Description
Set or query the GPIB address.
Parameter
Name
Type
Range
Default
<adr>
Integer
1 to 30
2
Explanation
Return
Format
The query returns an integer.
Example
:SYSTem:GPIB 7
:SYSTem:LANGuage
Syntax
:SYSTem:LANGuage <lang>
:SYSTem:LANGuage?
:SYSTem:LANGuage?
Description
Set or query the system language.
Parameter
Name
Type
Range
Default
<lang>
Discrete
{SCHinese|ENGLish}
SCHinese
Explanation
Return
Format
The query returns SCH or ENGL.
Example
:SYSTem:LANGuage SCHinese
:SYSTem:LOCKed
Syntax
:SYSTem:LOCKed <bool>
:SYSTem:LOCKed?
:SYSTem:LOCKed?
Description
Open or close the keyboard lock function, or query the status of the keyboard lock
function.
Parameter
Name
Type
Range
Default
<bool>
Bool
{{0|OFF}|{1|ON}}
0|OFF
Return
Format
The query returns 0 or 1.