Rigol MSO1074Z-S 4-channel oscilloscope, Digital Storage oscilloscope, MSO1074Z-S Manuel D’Utilisation
Codes de produits
MSO1074Z-S
RIGOL
DS1000Z Programming Guide
2-79
:TIMebase Commands
:TIMebase commands are used to set horizontal parameters, such as enabling the delayed sweep, setting
the horizontal timebase mode, etc.
Command List:
:TIMebase:DELay:ENABle
Syntax
:TIMebase:DELay:ENABle <bool>
:TIMebase:DELay:ENABle?
:TIMebase:DELay:ENABle?
Description
Enable or disable the delayed sweep, or query the status of the delayed sweep.
Parameter
Name
Type
Range
Default
<bool>
Bool
{{0|OFF}|{1|ON}}
0|OFF
Explanation
Delayed sweep can be used to enlarge a length of waveform horizontally to view the
waveform details.
Return Format
The query returns 0 or 1.
Example
:TIMebase:DELay:ENABle ON
:TIMebase:DELay:OFFSet
Syntax
:TIMebase:DELay:OFFSet <offset>
:TIMebase:DELay:OFFSet?
:TIMebase:DELay:OFFSet?
Description
Set or query the delayed timebase offset. The default unit is s.
Parameter
Name
Type
Range
Default
<offset> Real
-(LeftTime -DelayRange/2) to
(RightTime -DelayRange/2)
(RightTime -DelayRange/2)
0
Explanation
LeftTime = 6×MainScale – MainOffset
RightTime = 6×MainScale + MainOffset
DelayRange = 12×DelayScale
Return Format
The query returns the offset in scientific notation.
Example
:TIMebase:DELay:OFFSet 0.000002 /*Set the delayed timebase offset to 2μs*/
:TIMebase:DELay:OFFSet? /*The query returns 2.0000000e-06*/
Related