Rigol MSO1074Z-S 4-channel oscilloscope, Digital Storage oscilloscope, MSO1074Z-S Manuel D’Utilisation
Codes de produits
MSO1074Z-S
RIGOL
2-80
DS1000Z Programming Guide
:TIMebase:DELay:SCALe
Syntax
:TIMebase:DELay:SCALe <scale_value>
:TIMebase:DELay:SCALe?
:TIMebase:DELay:SCALe?
Description
Set or query the delayed timebase scale. The default unit is s/div.
Parameter
Name
Type
Range
Default
<scale_value> Real
See
Explanation
500ns
Explanation
The maximum of <scale_value> is the main timebase scale currently set and the
minimum is related to the current sample rate (satisfying the inequality: current
sample rate * delay timebase scale * 7 ≥ 14) and not less than 1ns.
The delay timebase scale is only the maximum or the value decreased from the
maximum in 1-2-5 step. If the minimum calculated by the inequality mentioned
above is not the values which can be set, the larger value will be the minimum. If
the value set is between two values which can be set, the smaller one will be set.
For example, when the main timebase scale currently set 10.00us and the sample
rate is 500MSa/s, the maximum of <scale_value> is 10.00us. The minimum is
calculated using the inequality: ≥ 14 / (500MSa/s * 7) = 40ns. Taking the larger
value which can be set, the minimum is 50ns. At this point, if 0.000009 (namely
9us)is set, the instrument sets the delay timebase scale to 5us.
Return Format
The query returns the scale in scientific notation.
Example
:TIMebase:DELay:SCALe 0.00000005 /*Set the delayed timebase scale to 50ns*/
:TIMebase:DELay:SCALe? /*The query returns 5.0000000e-08*/
Related
Command
:TIMebase[:MAIN]:OFFSet
Syntax
:TIMebase[:MAIN]:OFFSet <offset>
:TIMebase[:MAIN]:OFFSet?
:TIMebase[:MAIN]:OFFSet?
Description
Set or query the main timebase offset. The default unit is s.
Parameter
Name
Type
Range
Default
<offset> Real
-Screen/2 to 1s or -Screen/2 to 5000s
0
Explanation
This command is invalid when the horizontal timebase is Roll and the oscilloscope
is in Run state.
When the horizontal timebase is YT and the timebase scale is 20ms or larger
(namely “Slow Sweep” mode), this command is invalid when the oscilloscope in
Stoping.
Return Format
The query returns the offset in scientific notation.
Example
:TIMebase:MAIN:OFFSet 0.0002 /*Set the main timebase offset to 20ms*/
Related
Command