Beha Amprobe GT-800 PRO KITVDE-tester 4472081 Manuel D’Utilisation

Codes de produits
4472081
Page de 76
GT-600/GT-800 Instruction Manual 
31 
 
 
Power, Load Current Test (P/I
L
 
The power/load current test measures the apparent power S, active power P
A
mains voltage U
LN
, load current I
L
 and power factor PF of the appliance, 
connected to mains test/mains socket. 
 
 
Warning
 
  NEVER carry out this test unless you have first carried out a thorough 
visual inspection, followed by a test of the protective bonding resistance 
(for class I appliances), and then a test of insulation resistance and 
protective conductor current or touch leakage test. You must verify that 
these tests have passed before engaging this test. 
 
 
Caution
 
  Live test! The appliance will be energized at mains voltage. For this 
purpose, switch on the appliance. Appliances driven by motors or 
equipped with heating units may present a danger for the person 
testing (comply with the appliance instruction manual!). Ensure that the 
appliance is in a safe condition to run and secure it prior to testing. 
 
Remarks: 
  Connect the appliance according to the figure 21. 
  If the load current is higher than 18.0 A for 10 seconds, the test will be 
interrupted automatically and “RANGE OVERLOAD” message will be 
displayed. 
 
 
 
Figure 21: Power / Load current test connection