AUTO-TEST Menu 
 
In this menu the following selections are available: 
 
MODIFY / VIEW: 
Modify/view (customer-created AUTO Tests) or just view 
(factory-programmed AUTO Tests).  
 
Select the AUTO Test you wish to modify/view first by 
using the “A
▼” and “A▲” menu keys then confirm the 
MODIFY/VIEW selection by pressing the “
” menu key.  
 
Now use the “
▼”, “▲” menu keys to select the desired 
AUTO Test step. 
 
At customer-created AUTO Tests two menu keys “EDIT” 
and “PAR” appear which allow the modification of the 
selected AUTO Test step. “EDIT” key enables to remove 
or add test step, “PAR” key enables to modify limit value 
or test parameter (e.g. test voltage in R
ISO
 function). 
 
RENAME AUTO-TEST: 
Select the AUTO Test you wish to rename first by using 
the “A
▼” and “A▲” keys then confirm the RENAME 
AUTO Test selection by pressing the “
” key. Use the 
▼”, “▲” and “
” menu keys to create new name, 
then confirm the new name by pressing the “
” key.  
 
CREATE AUTO-TEST: 
Create new AUTO Test as follows: 
-
  Create the name of the new AUTO Test by using the 
▼”, “▲” and “
” menu keys then confirm the 
name by pressing the “
” key. 
-
  Select protection class of the new AUTO Test (PC I or 
PC II) then confirm it by pressing the “
” key. 
-
  Select the tests to be contained in the new AUTO Test 
by using the rotary switch and confirm each individual 
test by the “
” key. End the selection by pressing the 
“END” key, the display turns to EDIT/ADJ mode. 
 
Notes for setup of new AUTO Test! 
  Test current in R
PE
 test (5 A or 0.2 A) and test voltage in R
ISO
 test (500 V (HI) 
or 250 V (LO)) can be selected by using the menu keys “Im” and “U
ISO
” 
during setup of new AUTO Test. 
  Measurement range in CLAMP test (0 ... 60 A (HI) or 0 ... 20 mA (LO)) can be 
selected by using the menu key “RNG” during setup of new AUTO Test. 
  Limit value in R
PE
 test is always copied from individual R
PE
 test. 
  Limit value in P/I
L
 test is always set to 3.7 kVA. 
  There is no limit value available in CLAMP test. 
  Limit value in all other tests is always set to standard value. 
  Edit (add/remove some tests) the AUTO Test by using the “EDIT” menu key 
or adjust limit values and/or test parameters by using the “PAR” menu key. 
 
COPY AUTO-TEST: 
Select the AUTO Test you wish to copy first by using the 
 “A
▼” and “A▲” menu keys then confirm the COPPY  
 
AUTO-TEST selection by pressing the “
” menu key. 
 
Confirm/abort offered selection by pressing the “YES” / 
 
”NO” menu key.