Posital Fraba ACS-080-2-CA01-HE2-PM Inclination Sensor 2 axes Reading range(s) -80/+80 ° ACS-080-2-CA01-HE2-PM Manuel D’Utilisation

Codes de produits
ACS-080-2-CA01-HE2-PM
Page de 44
 
ACS CANopen Manual 
 
 
 
 
 
 
 
 
 
 
 
Version 20110928 
 
 
 
7 of 44 
AC C E L E N S   ( AC S )  C AN o p e n  
2.1 Operating Modes 
2.1.1 Mode: Preoperational 
 
When the device is in this state, its configuration 
can  be  modified.  However,  only  SDOs  can  be 
used to read or write device-related data.  
 
The device goes into "Pre-Operational" state: 
•  After the power up, or 
•  On 
receiving 
the 
"Enter 
Pre-
Operational" NMT indication, if it was in 
Operational state. 
 
When configuration is complete, the device goes 
into  one  of  the  following  states  on  receiving  the 
corresponding indication: 
 
•  "Stopped"  on  receiving  the  "Stop 
Remote Node" NMT indication, 
 
•  "Operational"  on  receiving  the  "Start 
Remote Node" NMT indication. 
 
To set a node to pre-operational mode, the master must send the following message: 
Identifier 
Byte 0 
Byte 1 
Description 
0 h  
80 h  
00  
NMT-PreOp, all nodes  
0 h  
80 h  
NN  
NMT-PreOp, NN  
NN: node number 
 
 
2.1.2 Mode: Start – Operational 
 
The device goes into the "Operational" state if it 
was  in  the  "Pre-Operational"  state  on  receiving 
the  "Start  Remote  Node"  indication.  When  the 
CANopen  network  is  started  using  the  "Node 
start"  NMT  services  in  "Operational"  state,  all 
device 
functionalities 
can 
be 
used. 
Communication can use PDOs or SDOs. 
 
NOTE:  Modifications  to  the  configuration  in 
"Operational"  mode  may  have  unexpected 
consequences  and  should  therefore  only  be 
made in "Pre-Operational" mode. 
 
To put one or all nodes in the start operational state, the master has to send the following message: 
Identifier  
Byte 0  
Byte 1  
Description  
0 h  
01 h  
00h 
NMT-Start, all nodes  
0 h  
01 h  
NN(in hex) 
NMT-Start, NN  
NN: node number