AC C E L E N S   ( AC S )  C AN o p e n  
 
2.1.3 Mode: Stop Operation 
 
The  device  goes  into  the  "Stopped"  state  on 
receiving  the  "Node  stop"  indication  (NMT 
service)  if  it  was  in  "Pre-Operational"  or 
"Operational"  state.  In  this  state,  the  device 
cannot  be  configured.  No service is available  to 
read  and  write  device-related  data  (SDO).  Only 
the  slave  monitoring  function  "Node  Guarding" 
remains active. 
 
To put one or all nodes in the stop operational state, the master has to send the following message: 
Identifier  
Byte 0  
Byte 1  
Description  
0 h  
02 h  
00h 
NMT-Stop, all nodes  
0 h  
02 h  
NN (in hex) 
NMT-Stop, NN  
NN: node number 
 
2.1.4 Re-initialization of the Inclinometer 
If a node is not operating correctly, it is advisable to carry out a reinitialization. 
Identifier 
Byte 0 
Byte 1  
Description  
0 h  
82 h  
00h 
Reset Communication  
0 h  
81 h  
NN (in hex) 
Reset Node  
NN: node number 
After reinitialization, the inclinometer accesses the bus in pre-operational mode. 
 
2.2 Transmission Modes 
 
Polled Mode 
By a remote-transmission-request telegram the connected host calls for the 
current  process  value.  The  inclinometer  reads  the  current  position  value, 
calculates  eventually set-parameters and sends  back the  obtained  process 
value by the same identifier. 
Cyclic Mode 
The  inclinometer  cyclically  transmits  (without  being  called  by  the  host)  the 
current  process  value.  The  cycle  time  can  be  programmed  in  milliseconds 
for values between 0 ms and 65536 ms. 
Sync Mode 
After  receiving  a  sync  telegram  by  the  host,  the  inclinometer  answers  with 
the  current  process  value.  If  more  than  one  node  number  (encoder)  shall 
answer after receiving  a sync telegram, the answer telegrams of the nodes 
will  be  received  by  the  host  in  order  of  their  node  numbers.  The 
programming of an offset-time is not necessary. If a node should not answer 
after each sync telegram on the CAN network, the  parameter sync counter 
can  be  programmed  to  skip  a  certain  number  of  sync  telegrams  before 
answering again.