Posital Fraba ACS-080-2-CA01-HE2-PM Inclination Sensor 2 axes Reading range(s) -80/+80 ° ACS-080-2-CA01-HE2-PM Fiche De Données

Codes de produits
ACS-080-2-CA01-HE2-PM
Page de 12
 
Page 3 
ACS-CANopen Industrial Datasheet 
Version 20120120 
 
 
ACCEL ENS INDUSTRIAL INCLINO METER  
CANOPEN INTERFACE 
 
MTBF Data 
Failure Rate [FIT] 
759 
MTBF [Hours] 
1,317,822 
MTBF [Years]  
150 
 
The above mentioned data were calculated for ACS’ electronics under the following conditions: 
SNA: Non-mobile operation 
Tu: 40°C - Mean component of ambient temperature 
Zf: Continuous operation for 8760 h per year 
 
Programmable Parameters 
 
Resolution per 1° 
The resolution parameter per 1° is used to program the desired 
number (1°, 0.1° and 0.01°) of steps per 1°.  
Preset Value 
The Preset value is the desired position value, which should be 
reached at a certain physical position of the axis. The position 
value is set to the desired process value by the preset parameter. 
Moving Avarage-Filter 
 
This filter can be used to adjust the bandwidth of measuring 
values to minimize the influence of vibration. Factory Setting: 
Moving average filter activated for 20 subsequent readouts. 
Digital Recursive Filter 
This filter can be used for weighting the last measured value with 
the last previous value. This is useful to suppress sudden peaks in 
the angle measurement. 
Transmission Rate 
Adjustable - Min. 20 kBaud; Max. 1 MBaud 
Factory Setting : 125 kBaud 
Address (Node ID) 
Adjustable from 1 to 127 
Factory setting: Node ID=1