Scheduling the installation 
 
Before the installation procedure, compile a layout plan, which shows the arrangement of the 
heating elements. Also record on this layout plan the place of the thermostat and the position of 
the floor sensor as well as the zones which will not be heated, for example built-in furniture, 
cupboards, socles, facilities, bathtubs etc.   
Afterwards calculate the heatable surface. Select the suitable heating element according to the 
above mentioned schedule. If the heatable surface is bigger than 10 m² apply two or more heating 
elements. Considering the length of the selected heating element, list the arrangement of the 
element on the layout plan. The distance between the heating element and the walls must not be 
smaller than 5 cm. Assure that the connection cables (cold conductors) can be installed at the 
thermostat. If the length of 2x4 m of each connection cable is not long enough, instruct the installer 
to extend them.  
On the figure 1 and 2 are examples for layout options.  
 
                     
Thermostat                                                                                                                                                                      Thermostat 
 
Figure 1, one heating element 
 
Figure 2, two heating elements 
 
 
Installation of the heating elements 
 
The heating elements FH L are constructed so that they can be laid fast and uncomplicated. The 
installation must be carried out by a qualified electrician and be made strictly in accordance with 
the appropriate Standards and Regulations. 
For safety reasons a switching device should be used which ensures an all-pole disconnection of 
this permanently fixed equipment. This can be, for example, a 2-pole F1 Protective Switch (with a  
3 mm gap.) 
   
Diagrammatic Information – Installation example 
 
Figure 3 
 
  
1 – Mains connection ~ 230 V 
  2 – Thermostat 
  3 – In-Wall-Distributor Socket 
  4 – Connection cable of the heating element 
  5 – Empty pipe for floor sensor 
  6 – Floor sensor 
  7 – Heating element 
  8 – Laminate 
  9 – Warmth-/Impact-sound insulation 
10 – Rough floor surface