Operation
7.2
Setting Programmable bq27421 Options
The bq27421 OTP comes configured per the default settings detailed in the bq27421 data sheet. Ensure
that the settings are correctly changed to match the pack and application for the bq27421 solution being
evaluated.
IMPORTANT: The correct setting of these options is essential to get the best performance. The settings
can be configured using the Data Memory window seen in the main GaugeStudio window (
Figure 9. Data Memory Screen
To read all the data from the bq27421 OTP, click on the Refresh button in the Data Memory window.
To make a RAM update and write to an OTP location, please make sure that the [CFGUPMODE] bit in the
Flags register is set by sending the SET_CFGUPDATE subcommand (0x0013). The SET_CFGUPDATE
subcommand can be sent to the bq27421 in GaugeStudio by clicking the SET_CFGUPDATE button in the
Commands window. However, GaugeStudio will handle the update of the OTP parameter(s) automatically
so the user will not have to worry about entering and exiting CONFIG UPDATE mode. To update an OTP
parameter, click on the desired parameter and a window will pop-up that provides details on the selected
OTP parameter. Next, enter the value in the value textbox and press Enter. After Enter has been
pressed, GaugeStudio will update the selected parameter. Please note that the OTP updates are stored in
RAM and a POR or full RESET subcommand (0x0041) will change the OTP back to the default value.
The Import button in the Data Memory window can be clicked in order to import an entire OTP
configuration from a specified *.gg file.