Keithley 6487/E Digital-Multimeter, DMM, 6487/E Fiche De Données
Codes de produits
6487/E
LO
W L
E
V
E
L M
E
A
S
U
R
E & S
O
U
R
C
E
www.keithley.com
1.888.KEITHLEY
(U.S. only)
A Greater Measure of Confidence
GENEral
AMMETER INPUT CONNECTOR: Three lug triaxial on
rear panel .
ANALOG OUTPUT CONNECTOR: Two banana jacks on
rear panel .
VOLTAGE SOURCE OUTPUT CONNECTOR: Two banana
jacks on rear panel .
INTERLOCK CONNECTOR: 4 pin DIN .
TRIGGER LINE: Available, see manual for usage .
DISPLAy: 12 character vacuum fluorescent .
DIGITAL FILTER: Median and averaging (selectable from
TRIGGER LINE: Available, see manual for usage .
DISPLAy: 12 character vacuum fluorescent .
DIGITAL FILTER: Median and averaging (selectable from
2 to 100 readings) .
RANGING: Automatic or manual .
AUTORANGING TIME
AUTORANGING TIME
3
: <250ms (analog filter off, 1PLC) .
OVERRANGE INDICATION: Display reads “OVRFLOW .”
CONVERSION TIME: Selectable 0 .01PLC to 60PLC (50PLC
CONVERSION TIME: Selectable 0 .01PLC to 60PLC (50PLC
under 50Hz operation) . (Adjustable from 200µs to 1s)
READING RATE:
To internal buffer 1000 readings/second
1
To IEEE-488 bus
900 readings/second
1, 2
BUFFER: Stores up to 3000 readings .
PROGRAMS: Provide front panel access to IEEE address,
PROGRAMS: Provide front panel access to IEEE address,
choice of engineering units or scientific notation, and
digital calibration .
digital calibration .
EMC: Conforms with European Union Directive 89/336/
EEC, EN61326-1 .
SAFETy: Conforms with European Union Directive 73/23/
EEC, EN61010-1, CAT I .
ENVIRONMENT:
Operating: 0°–50°C; relative humidity 70% non-
condensing, up to 35°C . Above 35°C, derate humidity
by 3% for each °C .
by 3% for each °C .
Storage: –10°C to +65°C .
WARM-UP: 1 hour to rated accuracy (see manual for rec-
ommended procedure) .
POWER: 100–120V or 220–240V, 50–60Hz, (50VA) .
PHySICAL:
PHySICAL:
Case Dimensions: 90mm high
× 214mm wide ×
369mm deep (3½ in .
× 8
3
⁄
8
in .
× 14
9
⁄
16
in .) .
Working Dimensions: From front of case to rear
including power cord and IEEE-488 connector:
394mm (15 .5 inches) .
394mm (15 .5 inches) .
NET WEIGHT: <4 .7 kg (<10 .3 lbs) .
NoTEs
1 . 0 .01PLC, digital filters off, front panel off, auto zero off .
2 . Binary transfer mode . IEEE-488 .1 .
3 . Measured from trigger in to meter complete .
2 . Binary transfer mode . IEEE-488 .1 .
3 . Measured from trigger in to meter complete .
Typical analog
5½ Digit
accuracy (1 Year)
1
rise Time (10% to 90%)
3
Default
±(% rdg. + offset)
Typical
Damping
4
range
resolution
18°–28°C, 0–70% rH
rMs Noise
2
off on
2 nA
10 fA
0 .3 % + 400 fA
20 fA
4 ms
80 ms
20 nA
100 fA
0 .2 % + 1 pA
20 fA
4 ms
80 ms
200 nA
1 pA
0 .15% + 10 pA
1 pA
300 µs
1 ms
2 µA
10 pA
0 .15% + 100 pA
1 pA
300 µs
1 ms
20 µA
100 pA
0 .1 % + 1 nA
100 pA
110 µs
110 µs
200 µA
1 nA
0 .1 % + 10 nA
100 pA
110 µs
110 µs
2 mA
10 nA
0 .1 % + 100 nA
10 nA
110 µs
110 µs
20 mA
100 nA
0 .1 % + 1 µA
10 nA
110 µs
110 µs
TEMPERATURE COEFFICIENT: 0°–18°C & 28°–50°C . For each °C, add 0 .1
× (% rdg + offset) to accuracy spec .
INPUT VOLTAGE BURDEN: <200µV on all ranges except <1mV on 20mA range .
MAXIMUM INPUT CAPACITANCE: Stable to 10nF on all nA ranges and 2µA range; 1µF on 20µA and 200µA ranges, and on
MAXIMUM INPUT CAPACITANCE: Stable to 10nF on all nA ranges and 2µA range; 1µF on 20µA and 200µA ranges, and on
mA ranges .
MAXIMUM CONTINUOUS INPUT VOLTAGE: 505 VDC .
NMRR
NMRR
1
: (50 or 60Hz): 60dB .
ISOLATION (Ammeter Common or Voltage Source to chassis): Typically >1
×10
11
W in parallel with <1nF .
MAXIMUM COMMON MODE VOLTAGE (between chassis and voltage source or ammeter): 505 VDC .
ANALOG OUTPUT: Scaled voltage output (inverting 2V full scale on all ranges): 2 .5% ±2mV .
ANALOG OUTPUT IMPEDANCE
ANALOG OUTPUT: Scaled voltage output (inverting 2V full scale on all ranges): 2 .5% ±2mV .
ANALOG OUTPUT IMPEDANCE
3
: <100
W, DC–2kHz .
VOLTAGE SOURCE:
accuracy
5
Noise
Typical
Typical
range step size
±(% prog. + offset)
(p-p)
Temperature
rise Time
6, 8
fall Time
7, 8
(Max.) (typical) 18°–28°C, 0–70% r.H. 0.1–10 Hz
Coefficient
(10%–90%)
(90%–10%)
±10 .100
200 µV
0 .1 % + 1 mV
<50 µV (0 .005% + 20 µV)/°C
250 µs
150 µs
±50 .500
1 mV
0 .1 % + 4 mV
<150 µV (0 .005% + 200 µV)/°C
250 µs
300 µs
±505 .00
10 mV
0 .15% + 40 mV
<1 .5 mV (0 .008% + 2 mV)/°C
4 .5 ms
1 ms
SELECTABLE CURRENT LIMIT: 2 .5mA, 250µA, 25µA for 50V and 500V ranges, 25mA additional limit for 10V range . All current lim-
its are –20%/+35% of nominal .
WIDEBAND NOISE
9
: <30mVp-p 0 .1Hz–20MHz .
TyPICAL TIME STABILITy: ±(0 .003% + 1mV) over 24 hours at constant temperature (within 1°C, between 18°–28°C, after 5 minute
settling) .
OUTPUT RESISTANCE: <2 .5
W .
VOLTAGE SWEEPS: Supports linear voltage sweeps on fixed source range, one current or resistance measurement per step .
Maximum sweep rate: 200 steps per second . Maximum step count 3000 . Optional delay between step and measure .
RESISTANCE MEASUREMENT (V/I): Used with voltage source; resistance calculated from voltage setting and measured current .
Accuracy is based on voltage source accuracy plus ammeter accuracy . Typical accuracy better than 0 .6% for readings between 1k
W
and 1T
W .
ALTERNATING VOLTAGE RESISTANCE MEASUREMENT: Offers alternating voltage resistance measurements for resistances from
10
9
W to 10
15
W . Alternates between 0V and user-selectable voltage up to ±505V .
NoTEs
1 . At 1 PLC – limited to 60 rdgs/s under this condition .
2 . At 6 PLC, 1 standard deviation, 100 readings, filter off, capped input – limited to 10 rdgs/sec under this condition .
3 . Measured at analog output with resistive load >2k
2 . At 6 PLC, 1 standard deviation, 100 readings, filter off, capped input – limited to 10 rdgs/sec under this condition .
3 . Measured at analog output with resistive load >2k
W .
4 . Maximum rise time can be up to 25% greater .
5 . Accuracy does not include output resistance/load regulation .
6 . Rise Time is from 0V to ± full-scale voltage (increasing magnitude) .
7 . Fall Time is from ± full-scale voltage to 0V (decreasing magnitude) .
8 . For capacitive loads, add C·
5 . Accuracy does not include output resistance/load regulation .
6 . Rise Time is from 0V to ± full-scale voltage (increasing magnitude) .
7 . Fall Time is from ± full-scale voltage to 0V (decreasing magnitude) .
8 . For capacitive loads, add C·
∆V/ILimit to rise time, and C·∆V/1mA to fall time .
9 . Measured with LO connected to chassis ground .
rEMoTE oPEraTIoN
IEEE-488 BUS IMPLEMENTATION: SCPI (IEEE-488 .2,
SCPI-1996 .0); DDC (IEEE-488 .1) .
LANGUAGE EMULATION: Keithley Model 486/487
emulation via DDC mode .
RS-232 IMPLEMENTATION:
Supports: SCPI 1996 .0 .
Baud Rates: 300, 600, 1200, 2400, 4800, 9600, 19 .2k,
Baud Rates: 300, 600, 1200, 2400, 4800, 9600, 19 .2k,
38 .4k, 57 .6k .
Protocols: Xon/Xoff, 7 or 8 bit ASCII, parity-odd/even/
none .
Connector: DB-9 TXD/RXD/GND .
6487
Picoammeter/ Voltage Source
M
ode
l 6
48
7 s
pe
ci
fic
at
io
ns
M
ode
l 6
48
7 s
pe
ci
fic
at
io
ns