Emerson GXT2 4500VA/6000VA Extended Battery Cabinets + Ocwebcard GXT2-240VBATTK Manuel D’Utilisation

Codes de produits
GXT2-240VBATTK
Page de 8
The Right Features in Just the Right Size
On-line design means zero transfer time from external
to internal power. When utility power fails, your critical
load remains supported by a seamless flow of power
from the GXT2. 
For maximum control, the GXT2 is custom configurable to
your needs using a specially designed Windows software
package. Offered in 700, 1000, 1500, 2000, 3000, 4500,
and 6000 VA capacities, the GXT2 also provides easy servi-
ceability with user replaceable batteries. And all this is
available in one of the most affordable UPS systems in its
class.
Quality Power
The Liebert GXT2 is a true on-line power source, so whatever
the quality of power coming in - the pure sinewave output
meets the exacting standards of your equipment. 
Unlike other UPS technologies, the GXT2's design handles
all these potential power problems:
Power spikes and transients
EMI/RFI noise
Voltage sags and brownout conditions 
Harmonics
Power-factor corrected loads 
Outages 
Built-In Reliability 
The GXT2 is designed from the inside out for maximum 
reliability. It includes operating features that simply are not
available on other units in its price range:
• Power-factor corrected loads: 
The GXT2 maintains stable voltage output even 
with the power-factor corrected loads typical of 
modern computer equipment.
• Frequency conversion:
Allows 60Hz input/50Hz output or 50Hz input/60Hz 
output with no derating.
• Unlimited external battery connectability:
Any number of 2U/4U battery cabinets can be added 
to supply additional battery time.
• Internal automatic and manual bypass capability:
Assures continuity of power to critical loads during 
system problems or maintenance.
• Optional Maintenance Bypass and Output 
Power Distribution Box:
Allows for easy maintenance and safe operation on UPS 
or connected equipment during installation and routine
service operations.
Top Trim
(2 pieces; tower
use only)
Status Indicators & Controls
Upper Bezel
Lower Bezel & Battery Access Door
Battery 
Disconnect
External Battery Connector
UPS Output Circuit Breaker
DB-9 Communication
Port
Removable Power 
Distribution Box
Fans
REPO Connector
Relay Card Slot
Serial Card Slot 
(SNMP, OCWEB, USB)
DB-9 Communications Port
External Battery Connector
Output Sockets
Intellislot Port
Cooling Fan
AC Input
Support Base
GXT2 Tower Mode (2U, 700-3000VA version shown)
GXT2 Rack Mode (5U, 4500-6000VA version shown)