Bk Precision BK-8500 Electronic Load 1 mA - 30 A 0.1 - 120 Vdc 0 - 300 W BK-8500 Fiche De Données
Codes de produits
BK-8500
Models 8520/8522/8524/8526 (2400W & 5000W)
Parameter
8520
8522
8524
8526
Input rating
Voltage
0 – 120 V
0 – 500 V
0 – 60 V
0 – 500 V
Current
0 – 240 A
0 – 120 A
0 – 240 A
0 – 120 A
Power
2400 W
5000 W
8520/8522/8524/8526 common characteristics
Parameter
Range
8520
8522
8524
8526
Accuracy
Resolution
CV Mode
Regulation
0.1-18 V
±(0.05%+0.02% FS)
1 mV
0.1 V to Vmax
±(0.05%+0.025% FS)
10 mV
CC Mode
Regulation
0-24 A
0-12 A
0-24 A
0-12 A
±(0.1%+0.1% FS)
1 mA
0 – max Current
±(0.2%+0.15% FS)
10 mA
Current Measurement
0-12 A
0-3 A
0-24 A
0-12 A
±(0.1% + 0.1% FS)
1 mA
0 – max. Current
±(0.2%+0.15% FS)
10 mA
Voltage Measurement
0 – 18 V
8522/8526:
(0.02% + 0.02% FS)
8520/8524:
(0.02% + 0.025% FS)
(0.02% + 0.02% FS)
8520/8524:
(0.02% + 0.025% FS)
1 mV
0 - Vmax
±(0.02% + 0.025%FS)
10 mV
All DC load models
common characteristics for all DC load models
Parameter
Range
Accuracy
Resolution
CR Mode Regulation
Input current ≥FS 10%
Input Voltage≥FS 10%
Input Voltage≥FS 10%
0.1 -10 Ω
±(1%+0.3% FS)
0.001 Ω
10-99 Ω
±(1%+0.3% FS)
0.01 Ω
100-999 Ω
±(1%+0.3% FS)
0. 1 Ω
1K-4 KΩ
±(1%+0.8% FS)
1 Ω
CW Mode Regulation
Input current ≥FS 10%
Input Voltage≥FS 10%
Input Voltage≥FS 10%
0-100 W
±(1%+0.1% FS)
1 mW
100 W – max Power
±(1%+0.1% FS)
100 mW
Power Measurement
Input current ≥ FS 10%
Input Voltage ≥ FS 10%
0-100 W
±(1%+0.1% FS)
1 mW
100-max Power
±(1%+0.1% FS)
100 mW
Battery testing function
Input=0.1 V – 120 V Max measurement capacity= 999 A/H
Resolution =10 mA Timer range=1~60000 sec
Transition Mode
Range of Frequency 0.1 Hz-1 kHz Frequency error rate
<0.5%
NOTE: Specifications and information are subject to change without notice. Please visit
www.bkprecision.com for the most current product information.
www.bkprecision.com for the most current product information.
Environmental Conditions
This instrument is intended for indoor use in a pollution degree 2 environment. Operating
environmental limits are as follows:
environmental limits are as follows:
8500 DC Load Series
Version: September 2, 2009
Page 16 of 76