Atmel Xplained Pro Evaluation Kit ATSAM4E-XPRO ATSAM4E-XPRO Fiche De Données
![Atmel](https://files.manualsbrain.com/attachments/0369829915bda09f9c2e00fb805a7753579683b5/common/fit/150/50/8d2bf08978ec3e5bc63f4343ac5e91ce8d0e40045619fa520d910d64af8f/brand_logo.png)
Codes de produits
ATSAM4E-XPRO
SAM4E [DATASHEET]
Atmel-11157D-ATARM-SAM4E16-SAM4E8-Datasheet_12-Jun-14
1366
SETTLING: Analog Settling Time
ANACH: Analog Change
TRACKTIM: Tracking Time
Tracking Time = (TRACKTIM + 1) * AFEClock periods.
TRANSFER: Transfer Period
Transfer Period = (TRANSFER * 2 + 3) AFEClock periods.
USEQ: Use Sequence Enable
Value
Name
Description
0
AST3
3 periods of AFEClock
1
AST5
5 periods of AFEClock
2
AST9
9 periods of AFEClock
3
AST17
17 periods of AFEClock
Value
Name
Description
0
NONE
No analog change on channel switching: DIFF0, GAIN0 are used for all channels
1
ALLOWED
Allows different analog settings for each channel. See AFEC_CGR.
Value Name
Description
0
NUM_ORDER
Normal Mode: The controller converts channels in a simple numeric order.
1
REG_ORDER
User Sequence Mode: The sequence respects what is defined in AFEC_SEQR1 and
AFEC_SEQR2.
AFEC_SEQR2.