Trinamic TMCM-078 1-AXLE DRIVER 7A/75V 10-0075 Fiche De Données
![Trinamic](https://files.manualsbrain.com/attachments/3d3e5f379da870cbb393c25d96c9955d06328ccf/common/fit/150/50/45757a4b90d20190f61ff6ec66d18877f53ee7ac89b97ab92fb146d85e0a/brand_logo.gif)
Codes de produits
10-0075
TMCM-078 Manual (V1.03 / September 10th, 2008)
16
Copyright © 2008, TRINAMIC Motion Control GmbH & Co. KG
5.1.1.3 Operating Mode 2 (PHASE)
In Table 5.1 and Figure 5.1 examples of maximum power supply voltages regarding current I
COIL
and
inductivity of your motor are specified.
For further information, including a formula and description how to calculate the maximum voltage
for your setup, refer to 5.2.1.3
For further information, including a formula and description how to calculate the maximum voltage
for your setup, refer to 5.2.1.3
I
COIL
(RMS)
L (min.)
V
S
(max.)
7
0.536 mH
75 V
0.343 mH
48 V
0.171 mH
24 V
5.0
0,75 mH
75 V
0,48 mH
48 V
0,24 mH
24 V
4.0
0,94 mH
75 V
0,6 mH
48 V
0,3 mH
24 V
3.0 A
1,25 mH
75 V
0.8 mH
48 V
0.4 mH
24 V
2.0 A
1,875 mH
75 V
1.2 mH
48 V
0.6 mH
24 V
1.0 A
3,75 mH
75 V
2.4 mH
48 V
1.2 mH
24 V
0.5 A
7,5 mH
75 V
4.8 mH
48 V
2.4 mH
24 V
Table 5.1: Maximum voltage regarding motor current and inductivity
Figure 5.1: Maximum voltage regarding motor current and inductivity
Any combination of motor coil current and inductivity which is above the curve for maximum supply
voltage (V
S
) is possible to drive the motor in this mode. Check your motor data sheet, please.
0
1
2
3
4
5
6
7
8
0,5
1,5
2,5
3,5
4,5
5,5
6,5
L
/
m
H
ICOIL /A
75V
48V
24V