5.1.1.3  Operating Mode 2 (PHASE)  
In Table 5.1 and Figure 5.1 examples of maximum power supply voltages regarding current I
COIL
 and 
inductivity of your motor are specified. 
For  further information, including a  formula and description how to calculate the  maximum  voltage 
for your setup, refer to 5.2.1.3 
 
I
COIL
 (RMS) 
L (min.) 
V
S
 (max.) 
0.536 mH 
75 V 
0.343 mH 
48 V 
0.171 mH 
24 V 
5.0 
0,75 mH 
75 V 
0,48 mH 
48 V 
0,24 mH 
24 V 
4.0 
0,94 mH 
75 V 
0,6 mH 
48 V 
0,3 mH 
24 V 
3.0 A 
1,25 mH 
75 V 
0.8 mH 
48 V 
0.4 mH 
24 V 
2.0 A 
1,875 mH 
75 V 
1.2 mH 
48 V 
0.6 mH 
24 V 
1.0 A 
3,75 mH 
75 V 
2.4 mH 
48 V 
1.2 mH 
24 V 
0.5 A 
7,5 mH 
75 V 
4.8 mH 
48 V 
2.4 mH 
24 V 
Table 5.1: Maximum voltage regarding motor current and inductivity 
 
 
Figure 5.1: Maximum voltage regarding motor current and inductivity 
 
Any combination of motor coil current and inductivity which is above the curve for maximum supply 
voltage (V
S
) is possible to drive the motor in this mode. Check your motor data sheet, please.  
0
1
2
3
4
5
6
7
8
0,5
1,5
2,5
3,5
4,5
5,5
6,5
L
 /
m
H
ICOIL /A
75V
48V
24V