Ebm Papst Axial fan 24 Vdc 570 m³/h (W x H x D) 119 x 119 x 38 mm 4114 N/2H8P Manuel D’Utilisation

Codes de produits
4114 N/2H8P
Page de 4
page 3 of 4 
Cleaning 
 
 
 
NOTE 
Product damaged during cleaning
 
 
 
Clean the product carefully with a 
moist cloth without applying 
pressure to the rotor. Do not use 
cleaning agents that contain acids, 
caustic solutions or solvents. 
 
 
Disposal 
 
When disposing of the product, observe all requirements and 
regulations that are relevant in your country. 
 
INTENDED USE
 
 
The product is designed exclusively as a built-in device for conveying 
air according to the technical data. 
Every use that is not in accordance with the intended purpose, is 
regarded as misuse of the product. 
On-site installations must comply with the mechanical, thermal and 
service life requirements, see Chapter 3, Technical Data. 
 
Intended use includes: 
 
-  Operating the product with all protective equipment 
-  Do not put the product into operation before it has been installed in 
the customer's application 
-  Observation of the operating manual 
 
Use for other than the intended purpose 
 
Using the product for the purposes mentioned below is prohibited and 
can be dangerous: 
 
-  Conveyance of air that contains abrasive particles. 
-  Conveyance of air that has a highly corrosive effect. 
-  Conveyance of air that has a high dust load, e.g. vacuuming 
sawdust. 
-  Conveyance of inflammable gases/particles. 
-  Contact with materials that can damage the product, e.g. acids, 
caustic solutions, solvents. 
-  Exposure to radiation that can damage product components, e.g. 
strong UV rays or thermal radiation. 
-  Operating during external vibration. 
-  Operating the product close to inflammable materials or 
components. 
-  Operating the product in an explosive atmosphere 
-  Use of the prouct as a safety component or for performing safety-
relevant functions. 
-  Operating in medical devices with life-sustaining or life-saving 
function. 
-  Operating in non-stationary systems, e.g. railway vehicles, aircraft 
and spacecraft. 
-  Operating with fully or partially dismantled or manipulated protective 
equipment. 
-  Operating the product under conditions other than those mentioned 
in the technical data. 
-  Furthermore, all fields of application not mentioned under intended 
use. 
 
An in situ assessment must be conducted of the heating behavior 
(appropriate and inappropriate operation), the protection against 
contact, electrical shocks, impact of foreign objects or water and the 
usage at altitudes higher than 2000 meters. 
 
Contact ebm-papst if you have specific queries regarding the product. 
TECHNICAL DATA
 
 
Drawing, see annex 
 
Technical description 
 
Airflow direction 
Air intake over struts 
Rotational direction 
looking at rotor 
clockwise 
Nominal voltage 
24,0 V 
Current consumption 
5.500 mA 
Power consumption 
130,0 W 
Speed 
11.000 1/min 
Max. free-air flow 
565,0 m3/h 
Weight 
0,425 kg 
Protection class 
III 
Max. torque when 
mounted across both 
mounting flanges 
wire outlet corner: 420 Ncm 
remaining corners: 600 Ncm 
Screw size 
ISO 4762 - M4 degreased, 
without an additional brace and 
without washer 
 
The product is intended for use in sheltered rooms with controlled 
temperature and controlled humidity. Directly exposure to water must 
be avoided. 
 
Pollution degree 1 (according DIN EN 60664-1) 
There is either no pollution or it occurs only dry, non-conductive 
pollution. The pollution has no negative impact. 
 
Ambient conditions 
 
Permitted ambient temperature 
Transport and storage 
Operation 
-40 °C ... 80 °C 
-20 °C ... 75 °C 
 
Vibration and shock load 
 
At stationary operation: 
 
sinus vibration 
1,0 g; 5 - 500 Hz; 3 x 1 sweep 
(Resonance search run) 
Noise 
0,5 m2/s3, 10 - 50 Hz; +12 
dB/oct f. 5 - 10 Hz; -12 dB/oct f. 
50 - 100 Hz; 3 x 30 min 
Repetitive shock 
Half sine; 5 g, 11 ms; 6 x 100 
shocks 
 
Transport and storage:  
 
Noise 
2,0 m2/s3, 5 - 20 Hz;  -3 dB/oct f. 
20 - 500 Hz; 3 x 30 min 
Thrusts 
Half sine; 18 g, 6 ms; 6 x 100 
shocks 
 
Do not operate your product in the resonance range.  
CONNECTION AND COMMISSIONING
 
 
Connect mechanical parts 
 
 
CAUTION 
Risk of cutting/squashing when 
removing the product from the 
packaging and during mounting. 
 
Grasp the housing and lift the product 
carefully out of the packaging. Avoid 
impact. 
 
Wear safety boots and cut-resistant 
gloves. 
 
 
NOTE 
Risk of damage to electronic 
components. 
 
 
Use ESD protective equipment when 
mounting. 
 
 
 
Connect electrical parts 
 
Connect to the mains after installation.