Motion control is easy 
 
10.6 Operation of motion control for S7-1200 
Easy Book 
Manual, 03/2014, A5E02486774-AF 
243
 
The table below shows the default I/O assignments; however, the four pulse generators can 
be configured to any digital output. 
 
 
Note 
Pulse-train outputs cannot be used by other instructions in the user program. 
When you configure the outputs of the CPU or signal board as pulse generators (for use with 
the PWM or motion control instructions), the corresponding output addresses no longer 
control the outputs. If your user program writes a value to an output used as a pulse 
generator, the CPU does not write that value to the physical output. 
 
 
Note 
PTO direction outputs can be freed for use elsewhere in your program. 
Each PTO requires the assignment of two outputs: one as a pulse output and one as a 
direction output. You can use just the pulse output and not the direction output. You can then 
free the direction output for other purposes in your user program. The output cannot be used 
for both the PTO direction output and in the user program, simultaneously. 
 
 
Table 10- 35  Default address assignments of the pulse and direction outputs 
Usage of outputs for motion control 
 
Pulse 
Direction 
PTO1 
 
Built-in I/O 
Q0.0 
Q0.1 
SB I/O 
Q4.0 
Q4.1 
PTO2 
 
Built-in I/O 
Q0.2 
Q0.3 
SB I/O 
Q4.2 
Q4.3 
PTO3 
 
Built-in I/O 
Q0.4
1
 
Q0.5
1
 
SB I/O 
Q4.0 
Q4.1 
PTO4 
 
Built-in I/O 
Q0.6
2
 
Q0.7
2
 
SB I/O 
Q4.2 
Q4.3 
 
1
  The CPU 1211C does not have outputs Q0.4, Q0.5, Q0.6, or Q0.7. Therefore, these outputs 
cannot be used in the CPU 1211C. 
  The CPU 1212C does not have outputs Q0.6 or Q0.7. Therefore, these outputs cannot be used in 
the CPU 1212C. 
3
  This table applies to the CPU 1211C, CPU 1212C, CPU 1214C, CPU 1215C, and CPU 1217C 
PTO functions.