Hawker Energy , 6V Ah lead acid battery 4533 4533 Fiche De Données

Codes de produits
4533
Page de 20
 
Each plastic Monobloc consists of Single Cell elements, 
internally connected to provide a 4 or 6 volt unit. 
Monoblocs or Single Cells can be connected in series 
or parallel to achieve the required voltage or capacity. 
Monoblocs and Single Cells are supplied with spade 
terminals making electrical connections quick and easy. 
Additionally, EnerSys
®
 products offer the highest vent 
pressure in the market. As a result, our batteries are 
more resistant to venting and dryout from continuous 
overcharge in standby applications. 
8.  Fastest recharge - EnerSys pure lead chemistry 
allows our batteries and cells to offer the highest 
recharge efficiency of any sealed-lead battery on the 
market. With pure lead, you can achieve a 95% 
state of recharge in less than one hour - without loss 
of capacity or electrolyte using conventional 
constant-voltage charging techniques.
 
Flexible charging options are possible with CYCLON
®
 
battery Single Cells and Monoblocs, as no current limit is 
required when using a constant voltage charger.
9. Orientation/placement/transport - Due to the products' 
mechanical design, CYCLON batteries can be mounted 
and operated in any position, an attractive feature for less 
accessible areas.
 
CYCLON battery Single Cells offer UL 94V-0 flame-
retardant packaging, thus allowing the mounting of 
systems in sensitive areas and human environments. 
Plus, the unique and flexible 2-volt CYCLON battery 
Single Cell allows you to design your system using 
an almost infinite number of packaging/design 
configurations.
 
Effective September 30, 1995, CYCLON battery Single 
Cells and Monoblocs were classified as “nonspillable 
batteries”, and are excepted from the Department of 
Transportation's comprehensive packaging requirements 
if the following conditions are satisfied: (1) The battery 
is protected against short circuits and is securely 
packaged and (2) The battery and outer packaging 
must be plainly and durably marked “NONSPILLABLE” 
or “NONSPILLABLE BATTERY”. CYCLON battery 
shipments from the EnerSys plant in Warrensburg, 
Missouri will be properly labeled in accordance with 
applicable regulations. Packaging changes performed 
at other locations may require additional labeling, since 
in addition to the battery itself containing the required 
marking, the outer packaging of the battery must also 
contain the required marking: “NONSPILLABLE” or 
“NONSPILLABLE BATTERY”. 
 CYCLON 
battery 
Single Cells and Monoblocs have been 
tested and determined to be in compliance with the 
vibration and pressure differential tests contained in 49 
CFR 
§
 173.159(d).
 Because 
CYCLON 
battery Single Cells and Monoblocs 
are classified as “Nonspillable” and meet the conditions 
above, [from 
§
 173.159(d)] they do not have an assigned 
UN number nor do they require additional DOT hazard 
labeling.
 
The regulation change effective September 1995, was 
to clarify and distinguish to shippers and transporters, 
all batteries that have been tested and determined to 
be in compliance with the DOT Hazardous Material 
Regulations, the International Civil Aeronautics 
Organisation (ICAO), and the International Air Transport 
Association (IATA) Packaging Instruction 806 and Special 
Provision A67, and therefore excepted from all other 
requirements of these regulations and classified as a 
“nonspillable battery”.
10. Shelf life - Pure lead batteries have an extremely low 
self-discharge rate, thus providing extended storage 
capability while maintaining high state-of-charge levels 
for dependable operation.
 CYCLON 
battery 
Single Cells and Monoblocs have 
a shelf life more than two times that of conventional 
lead batteries. To assure maximum reliability, EnerSys 
recommends that all stored cells/batteries be recharged 
(boost charged) once every 24 months or when the open 
circuit voltage drops to 2.00 volts per cell, whichever 
occurs earlier. Inventory should be checked more 
frequently if storage temperature regularly exceeds 25°C.
The pure lead advantage
6
Publication No: EN-CYC-SG-003 - December 2008
www.enersys-emea.com