Hawker Energy , 6V Ah lead acid battery 4533 4533 Fiche De Données

Codes de produits
4533
Page de 20
There is no need to limit the inrush current to the battery 
during constant voltage charging. The low internal 
resistance of EnerSys
®
 CYCLON
®
 battery Single Cells and 
Monoblocs allows for large inrush current without damage.
Since not all of the charge returned is accepted to replenish 
the electro-chemical potential, a good rule of thumb to use 
is that the charge returned should be 105% to 110% of the 
capacity delivered on the previous discharge.
Most current waveforms are not pure DC nor are they pure 
sine waves. Therefore, consult the EnerSys Application 
Support Department for assistance when evaluating the 
charger current waveforms for your specific application.
A three-step 6-8 hour charge profile optimised for CYCLON 
cells and batteries is available on request from the Technical 
Support Department of EnerSys.
  
 
 
Internal  Nominal
 
 
 
 
res. of fully 
short circuit 
 
 
Height with 
 Products  Capacity 
Part  
charged cell 
current for 
Diameter 
Height 
terminals 
Weight 
Tabs
  
  Number 
 
mΩ @ 25°C  charged cell 
in.   mm 
in.     mm 
in.    mm 
oz.    gm  
in.             mm
 
D cell  
2.5Ah 
0810-0004 
5.0 
400A 
1.35   34.3 
2.41   61.2 
2.68   68.1 
6.28   178.0 
.187x.025  4.75x0.64
  DT cell  
4.5Ah 
0860-0004 
5.0 
400A 
1.35   34.3 
3.78  96.0 
4.05  102.9 
9.68   274.4 
.187x.025   4.75x0.64
 
X cell  
5.0Ah 
0800-0004 
3.5 
570A 
1.75  44.5 
2.87  72.9 
3.21  81.5 
12.77  362.0 
.250x.025   6.35x0.64
 
E cell  
8.0Ah 
0850-0004 
3.0 
665A 
1.75  44.5 
3.94  100.1 
4.28  108.7 
17.28  489.9 
.250x.025   6.35x0.64
 J 
cell  12.0Ah 0840-0004 
2.5 
800A 
2.04 51.8 
4.85 
123.2 
5.34 
135.6  29.60 
839.2 
.312x.032 7.92x0.81
  BC cell  
25Ah 
0820-0004 
1.5 
1335A 
2.57  65.3 
6.25  158.8 
6.82  173.2 
58.88 1669.2 
M6 (-) and
 
    
 
   
  
   
  
 
M8 
(+) 
terminals
DIMENSIONS
  
 
  Internal 
res. 
Nominal
 
 
 
 
of fully charged short circuit 
 
 
Height with 
 Products  Capacity 
Part  
Monobloc 
current for 
Diameter 
Height 
terminals 
Weight 
Tabs
  
  Number 
 
mΩ @ 25°C  charged cell 
in.   mm 
in.     mm 
in.    mm 
oz.    gm  
in.             mm
 
D cell  
2.5Ah 
0819-0010 
10.0 
400A 
3.13  79.5 
1.81  46.0 
2.75  69.9 
.80 
.36 
.187x.025  4.75x0.64
 
cell 
 
5.0Ah 
0809-0010 7.0 
570A  3.80 
96.5 2.12 
53.8 3.02 
76.7 1.62 
.74  .250x.025 
6.35x0.64
 
E cell  
8.0Ah 
0859-0010 
6.0 
665A 
3.81  96.8 
2.13  54.1 
4.00  101.6 
2.11  .96 
.250x0.25  6.35x0.64
DIMENSIONS
CYCLON
®
 Battery Product Family (All capacities at 10 hr. rate 25°C to 1.67Vpc)
CYCLON
®
 Battery 2V Single Cell:
CYCLON
®
 Battery 4V Monoblocs:
  
 
  Internal 
res. 
Nominal
 
 
 
 
of fully charged short circuit 
 
 
 Products  Capacity 
Part  
Monobloc 
current for 
Length 
Width 
Height  
Weight 
Tabs
  
  Number 
 
mΩ @ 25°C  charged cell 
in.   mm 
in.     mm 
in.    mm 
lb.    kg  
in.               mm
 
 
D cell  
2.5Ah 
0819-0012 
15.0 
400A 
4.48  113.8 
1.81  46.0 
2.75  69.9 
1.15 
.52 
.187x.025  4.75x0.64
 
X cell  
5.0Ah 
0809-0012 
10.0 
570A 
5.48  139.2 
2.12  53.8 
3.02  76.7 
2.16 
.98 
.250x0.25  6.35x0.64
 
E cell  
8.0Ah 
0859-0012 
8.0 
665A 
5.48  139.2 
2.13  54.1 
4.00  101.6 
3.15  1.43 
.250x0.25  6.35x0.64
DIMENSIONS
CYCLON
®
 Battery 6V Monoblocs:
8
Publication No: EN-CYC-SG-003 - December 2008
www.enersys-emea.com