Bosch Appliances Home Security System D1260B Manuel D’Utilisation

Page de 100
D1260/D1260B | Owner's Manual | Part III: Advanced Commands -  
 
 
Bosch Security Systems | 9/04 | 50410D 
63 
 
2.
 
Press the 
COMMAND key. The display shows 
*System Command*
 
3.
 
Press the 
5 key and then the 9 key. 
 
 
If you prefer, you may use the Command 
Menu in place of steps 2 and 3 to initiate 
this function. 
Press the MENU> soft key to enter the 
Command Menu. 
 
Press NEXT> soft key repeatedly. 
 
When you reach the DISPLAY REV ?> 
prompt, press its adjacent soft key. 
 
 
4.
 
The display will change to Radionics D9412* 
Version 6-40 
(D9412 and 6-40 are used as an example, other 
panels could be D9112, D7412, D7212) 
 
5.
 
The display will return to idle text after 5 seconds. 
 
 
SERVICE MENU ? (9 + 9 + Enter) 
The service menu is used to access the following 
commands: 
 
View Log - Use this function to review events in 
your system at your command center. Reviewing 
past events may help you identify problems. 
Viewing events does not require any additional 
equipment since the information is displayed at 
your command center. Events are stored in the 
panel’s memory in order of occurrence and tagged 
with the date and time. 
 
Print Log - The Print Log function lets you print 
the events stored in your security system’s log. You 
can choose to print the entire log or set a start date 
and print the events recorded from that date up to 
today. Your system must include a parallel printer 
interface and a printer to perform this function.
 
 
Display Rev (COMMAND + 5 + 9) - The 
command will retrieve the panel’s software version 
and display it. 
 
Service Walk (D9412/D9112 only) – The 
command will allow all the points on the system to 
be walk tested regardless of the type of point. For 
D7412 and D7212 panels this function must be 
added to the keypad’s menu. Contact your security 
company for more information. 
 
Default Text – This command will show the 
current state of the area for 3 seconds before 
returning to idle text. 
1.
 
Ensure your keypad shows idle disarmed text. 
 
2.
 
Press the 
9 key twice. 
3.
 
Press the 
ENTER key. 
4.
 
The display changes to show the service menu. 
 
Service Walk Test?>
 appears on D9412/D9112 
Panels only