Parameter Description: 
liu_id 
The identifier of the T1/E1 Line Interface Unit in the range 0 to one less than 
the number of LIUs fitted. This parameter can also be set to the special value 
0x83 to select the signaling processor instead of an LIU. In this case, 
timeslots 0 ... 3 correspond to signaling processor 0 ... 3 respectively. 
Note:   For the SPCI2S, valid values for the LIU identifiers are 2 and 3. 
timeslot 
The timeslot number on the T1/E1 line interface unit on which the data from 
the CT bus is transmitted. The valid range for timeslot is 1 to 31 for an E1 
interface and 1 to 24 for a T1 interface. 
sc_channel 
The channel number on the CT bus to which the LIU listens. This must be in 
the range 0 to one less than the total number of channels on the CT bus. 
Status Response 
The confirmation message (if requested) indicates success by status of zero. 
On error, the following status values can be found in the confirmation 
message. 
Value 
Mnemonic 
Description 
0xd2 
MVIP_INVALID_STREAM 
Invalid stream specified in listen request. 
0xd3 
MVIP_INVALID_TIMESLOT 
Invalid timeslot specified in listen request. 
0xff 
None 
Invalid message length.