Dialogic DSI SPCI Network Interface Boards Manuel D’Utilisation

Page de 111
6 Message Reference 
68 
timeslot 
The timeslot number on the T1/E1 line interface unit on which the fixed data 
is transmitted. The valid range for timeslot is 1 to 31 for an E1 interface and 
1 to 24 for a T1 interface. 
pattern 
The value of the fixed data to be generated. The value must be in the range 0 
to 255. Typical values are 0xff for an "all ones" idle pattern, or 0x2a for an 
ITU-T E1 idle pattern. 
Status Response 
The confirmation message (if requested) indicates success by status of zero. 
On error, the following status values can be found in the confirmation 
message. 
Value 
Mnemonic 
Description 
0xd2 
MVIP_INVALID_STREAM 
Invalid stream specified in listen request. 
0xd3 
MVIP_INVALID_TIMESLOT 
Invalid timeslot specified in listen request. 
0xff 
None 
Fixed pattern generation request failed. 
6.3.9 
Reset Switch Request 
Synopsis: 
Resets the digital switch to its default state in accordance with the current 
board configuration. 
Message Format: 
MESSAGE HEADER 
Field Name 
Meaning 
type MVD_MSG_RESETSWX (0x7e00) 
id 
src 
Sending Module ID 
dst MVD_TASK_ID (0x10) 
rsp_req 
used to request a confirmation 
hclass 
status 
err_info 
len