28 
 
Table 3.  Local Mode Programming Instructions - Continued 
Note: *Default Settings 
Function Code(s) 
Operation 
Normal Indication 
 
Remarks 
 
45 
46 
47 
48 
Drawer 1  
Open (45) 
Closed (46) 
 
Drawer 2  
Open (47) 
Closed (48) 
1. While in programming mode, at  the Series 500 Keyboard numeric keypad, enter 
applicable Function Code 45, 46, 47 or 48
  
       
LED (2) flashes.  
 
2. At the auxiliary keyboard, press the desired key or type the desired key sequence.  
Note that the maximum number of key codes is limited to  24  - this is equivalent to 
approximately 12 key strokes. 
 
       
 
 
 
 
If the  Series 500 Keyboard beeps and 
LED (2) turns off while entering key 
codes at the auxiliary keyboard, you 
have exceeded 24 key codes. Repeat 
steps 1 and 2. 
 
3. At the Series 500 Keyboard, press ENTER
 
       
LED (2) turns off.  
 
4. Program the next function code or exit programming mode by entering  99 on Series 
500 Keyboard numeric keypad or by swiping the Programmer's card.  If using the 
optional 3-position keyswitch, move switch out of the AUX position. 
49 
Poll/ 
Unsolicited  
Cash Drawer Status   
1. While in programming mode, at Series 500 Keyboard numeric keypad, enter Function 
Code 49. 
 
       
LED (2) turns on. 
 
2. At Series 500 Keyboard numeric keypad, enter the applicable number (0 or 1) to 
select status method per list below. 
 
       
0 = Send on change or transition 
       
1 = Send only with poll command CDSTATUS 
       
 
 
       
LED (2) turns off. 
 
3. Program the next function code or exit programming mode by entering 99 on Series 
500 Keyboard numeric keypad or by swiping the Programmer's card.  If using the 
optional 3-position keyswitch, move switch out of the AUX position.