Simrad AUTOPILOT SYSTEM AP50 Manuel D’Utilisation

Page de 188
Simrad AP50 Autopilot 
152 
20221032B
 
Counter rudder 
Counter Rudder is the parameter that counteracts for the effect 
of the boats turn rate and inertia. The default value depends on 
boat length. 
Range: 0.05 to 8.00. 
W Seastate  
As for Seastate above but applies for the Work-modes. 
W Rudder 
As for Rudder above but applies for the Work-modes. 
W Count rudder 
As for Counter rudder above but applies for the Work-modes. 
W Rudder limit 
This determines the maximum rudder movement, in degrees 
from the “used” midship position, that the autopilot can 
command the rudder in the WORK modes. 
Default: 10°. 
The W Rudder limit setting is only active during AUTO-
WORK and NAV-WORK steering on straight courses, NOT 
on course changes, but a Rudder Limit warning will be 
shown during course changes.
 
Cruising speed 
If the Cruising speed was not set during sea trial or needs to be 
changed, it can be set manually here. Refer to page 138. 
Range:   3 – 70 knots 
Default:   15 knots 
Speed response 
This adjusts the value for the Speed response (see page 143). 
Range:   0.00 – 2.00 
Default:   0.00