Grounding and Radio Frequency Interface 
(RFI) 
The AP50 system has excellent radio frequency interference 
protection and all units use the junction unit as a common 
ground/shield connection. The junction unit must therefore have 
a proper ground connection to the hull. 
RobNet cables and other signal cables (i.e. compass, feedback, 
NMEA) should not be run in parallel with other cables carrying 
radio frequency or high current, such as VHF and SSB 
transmitters, battery chargers/generators, and winches. 
 
Figure 4-12  J50 Junction Unit Screen Termination 
Remove the bottom cover to get access to the plug-in terminals. 
Strip about 1 cm (0.4 in.) of the cable's insulation and pull the 
screen backwards to cover the insulation. Position the straps as 
shown and tighten well to make sure the screen makes good 
contact. 
Provide sufficient wire length so that the plug-in terminals can 
be easily connected and disconnected. 
Pull out each terminal before connecting the wires. Remove all 
the strands before putting on the terminal cover. 
Junction Unit Terminals 
 
J50 Power Board Terminals 
Ground terminal 
Note! 
The Mains input 
is not polarity 
protected on the 
J50-40.