PS Audio P1000 Manuel D’Utilisation

Page de 6
• Up to 1000 watts power delivery - depending on 
load requirements.*
• Next generation MultiWave II technology featur-
ing AutoWave and TubeWave.
• Independent power zones keep power for ana-
log, digital and high current equipment electrically 
isolated.
• Regenerated AC delivered through 8 Power Port 
outlets.
• Filtered AC by High Current Ultimate Outlet™ 
delivered through 2 Power Port outlets.
• Front panel display for systems monitoring and 
user interface.
• Front panel displays waveform setting, output 
voltage, wattage and percentage of maximum 
power output. 
• Massive heat sinkinkg for silent operation
• Reduction of AC line noise by more than 70dB.
• High voltage surge suppression devices for 
surge and spike protection.
• Lower AC impedance for better transients.
• Insane toroidal transformer for extended head-
room.
• PS Audio’s brushed aluminum classic chassis.
• PS Bus for communication with other PS Audio 
devices. 
* Note about power consumption:
The  P1000  is  capable  of  delivering  up  to  1000  watts  into 
a  reactive  load  and  up  to  700  watts  into  a  resistive  load. 
Examples of a reactive load are: most solid state equipment 
and video products. An example of a resistive load is: tube 
based equipment. 
Quick Start Guide
1.
  Place  the  P1000  in  a  rack  or  on  a  shelf  in 
the  audio/video  system.  If  placed  on  carpet  it 
is  necessary  to  use  isolation  or  accessory  feet 
to  elevate  it  above  the  carpet  1  inch.  Failure  to 
do so could compromise the power regeneration 
capabilities of the P1000.
2. 
Connect audio/video equipment to the P1000. 
There are five electrically isolated duplex recep-
tacles  on  the  P1000,  which  are  oriented  verti-
cally. 
For  optimum  performance,  we  recommend  that 
equipment  with  medium  wattage  power  require-
ments  be  plugged  into  the  “Regenerated  AC” 
receptacles (2-ch preamps, AV processors, DVD/
CD players, Satellite receivers, PVR’s, D to A con-
verters, low power solid state amplifiers, etc). 
Equipment  with  extremely  high  wattage  power 
requirements should be plugged into the “Filtered 
AC” receptacles (direct view TVs, plasma or pro-
jection displays, multi-channel, tube or high pow-
ered amplifiers).
3. 
Plug the P1000 into a power source such as a 
wall outlet. Use the supplied AC power cable, or 
an  aftermarket  power  cable.  We  would  strongly 
urge the use of an xStream Power Cable.
4.
 Turn on the P1000 by pressing the power but-
ton located on the center of the front panel. The 
Regenerated  AC  zone  will  become  active.  The 
Filtered  AC  zone  immediately  becomes  active 
when the P1000 is plugged into a live outlet.
5. 
If desired, select a MultiWave II setting or allow 
AutoWave  to  adapt  to  the  power  needs  of  your 
system using the front panel controls.
Default settings
The P1000 comes from the factory with standard 
default  settings  that  should  work  well  for  most 
situations.  The  type  of  power  delivery  can  be 
configured  to  achieve  the  optimal  performance 
for any system.
3
up the P1000. If the Filtered AC outlets still do not 
pass AC, please contact your dealer for additional 
service.
The P1000 seems to be working, but the dis-
play is blank 
The P1000 may be in the display blanking mode. 
Press the Mode Up or Down buttons on the front 
panel and the display should turn back on.
My  turntable  or  fan  based  equipment  is  not 
operating normally
Any turntable or equipment with AC synchronous 
fans  should  not  be  used  with  MultiWave  II  or 
AutoWave.  These  products  must  be  used  with 
60Hz SINE mode or be plugged into the Filtered 
AC outlets. 
The P1000 shut down but the display is blank 
and the fuses are not blown
The P1000 has redundant thermal protection that 
will  shut  the  unit  down  in  the  event  the  internal 
temperature is too hot. If airflow is inadequate or 
room temperature is very warm and the P1000 is 
run  near  100%  capacity  for  very  long  periods  of 
time this type of shut-down may occur. The P1000 
will automatically turn back on when it has cooled 
sufficiently. If this occurs the load should be less-
ened  on  the  P1000  or  else  improve  the  airflow 
around the P1000.
Note:
The  following  display  messages  apply  only  to  the 
regenerator  circuit.  The  Power  Port  receptacle  dedi-
cated  to  the  built  in  High  Current  Ultimate  Outlet  will 
continue to pass AC.
The display is flashing “HOT!”
The P1000 will turn itself off and flash “HOT!” on 
the  display  if  it  detects  an  internal  temperature 
that exceeds safe operating limits. 
The P1000 will not power up during the cool down 
process.  The  P1000  is  ready  to  be  reactivated 
only after it returns to safe operating temperature, 
at this time the power button will become active. 
Please  use  this  time  to  reduce  the  load  that  is 
connected  to  the  Regenerated AC  outlets  of  the 
P1000. This message will be displayed when the 
P1000 is being overworked. 
The display is flashing a percentage
The P1000 will turn itself off and flash a percent-
age  (for  example,  “184%”)  on  the  display  if  it 
detects an over-current condition. 
If the current draw exceeds 100% of the P1000’s 
maximum recommended capacity for more than 3 
seconds, it will power down and display the over-
current amount. 
If the current draw exceeds 200% of the P1000’s 
maximum recommended capacity, it will instanta-
neously power down and display the over-current 
amount. 
Press the front panel power button once to clear 
the flashing display and again to turn the unit back 
on. If this message continues to appear, you must 
reduce the load on the P1000.
The display is flashing “SHORT”
The P1000 will  turn itself off and flash “SHORT” 
on  the  display  if  it  detects  an  electrical  short, 
which  means  a  product  connected  to  the  P1000 
is trying to draw too much current. This could be 
related to a defective power cable that is plugged 
into the back of the P1000. 
Press the front panel power button once to clear 
the flashing display and again to turn the unit back 
on. If it continues to flash “SHORT” disconnect all 
output  connections  from  the  back  of  the  P1000 
and power it up again. Be sure to check the power 
cables for any defects before plugging them back 
in.
If the display continues to read “SHORT” please 
contact your dealer for additional service. 
   
The display is flashing “FAULT”
The  P1000  will  turn  itself  off  and  flash  “FAULT” 
on the display if it detects a general hardware or 
software error. It is highly unlikely that the P1000 
will  ever  experience  this  condition,  but  FAULT 
indicator  has  been  built-in  to  ensure  proper  and 
long-term product reliability. 
If this message is displayed, simply turn the P1000 
10