Polycom Water System DOC2091A Manuel D’Utilisation

Page de 220
210
Appendix
Troubleshooting Guide
Global Management System User’s Guide
Software Update
Software Update Now doesn’t work. I get the following status: “Failed”, “Location 
Unspecified” and “File does not exist”
.
LOCATION UNSPECIFIED:
The softupdate.exe for a specific model indicates that the file was not uploaded onto the 
server.
FILE DOES NOT EXIST:
The softupdate.exe file was uploaded onto the server but was deleted from the server 
through some means other than Global Management System. 
FAILED:
This usually happens because Global Management System does not have the correct 
password for the video endpoint, or because the video endpoint was turned off or 
disconnected from the network.
You can find out the cause of the failure by looking at the update log for that system. The 
update log files are usually located in the 
drive:\Polycom\PWX\log\1_1_1_1_@_yyyy-mm-
dd-ss.log
on the Global Management System server machine, and they are named with the 
IP address of the ViewStation, followed by the date and time that the update was run. For 
instance, the file 111_11_11_111_@_2000-11-01-10-57-38.log is for the update that was 
run at 10:57:38, on Nov. 1, 2000, for the ViewStation at the address 111.11.11.111. Within 
this log, the message “Error in password” means that Global Management System does 
not have the correct password for this ViewStation. The message “Could not connect” 
means that the ViewStation was not responding.
Account Validation
I have created several accounts and set Account Validation on ViewStation to enable.  
When making video call, ViewStation always drop call even when I enter the correct 
account. To me, Account Validation does not work.
Account Validation only works with the first URL in the Manager URL list. If your 
ViewStation is being managed by more than 1 Global Management System, or if a 
previous Global Management System was shut down, and the ViewStation was then 
added to a new Global Management System, then you could have more than 1 URL in the 
Manager URL list on the ViewStation. 
Select that ViewStation in the Systems list, and click on the Management tab. You will see 
the list of URL’s for that ViewStation. Make sure that the address of Global Management 
System server where you created the accounts is in the first position.