4-2
4 DISTANCE MEASUREMENT
4.3
Distance Measurement (Continuous Measurement)
Make sure the mode displays angle measurement.
Operating procedure
Operation
Display
1
Collimate the center of prism.
Collimate P
2
Press the [
] key.
Distance measurement starts. *1),2)
[ ]
The measured distances are shown. *3)~*5)
●
Pressing the [
] key again, the display
changes to horizontal (HR) and vertical (V)angle
and slope distance(SD). *6)
and slope distance(SD). *6)
[ ]
*1) When EDM is working, the "
✻
" mark appears in the display.
*2) To change mode from Fine to Coarse or Tracking, refer to section 4.5 “Fine Mode/Tracking Mode/
Coarse Mode”.
To set the distance measurement on when the instrument is powered on, refer to Chapter 16
“SELECTING MODE”.
To set the distance measurement on when the instrument is powered on, refer to Chapter 16
“SELECTING MODE”.
*3) The distance unit indicator "m" (for meter) , "f" (for feet or feet inch) appears and disappears alternatively
with buzzer sounds at every renewal of distance data.
*4) Measurement may repeat automatically in the instrument if the result is affected by shimmer etc..
*5) To return to the normal measuring angle mode from a distance measuring mode, press the [ANG] key.
*6) It is possible to choose the display order (HR, HD, VD) or (V, HR, SD) for initial measuring distance
*5) To return to the normal measuring angle mode from a distance measuring mode, press the [ANG] key.
*6) It is possible to choose the display order (HR, HD, VD) or (V, HR, SD) for initial measuring distance
mode. Refer to Chapter 16 “SELECTING MODE”.
V : 90°10'20"
HR: 120°30'40"
HR: 120°30'40"
0SET HOLD HSET P1
↓
HR: 120°30'40"
HD*[r] << m
VD: m
MEAS MODE NP/P P1
HD*[r] << m
VD: m
MEAS MODE NP/P P1
↓
HR: 120°30'40"
HD* 123.456 m
VD: 5.678 m
MEAS MODE NP/P P1
HD* 123.456 m
VD: 5.678 m
MEAS MODE NP/P P1
↓
V : 90°10'20"
HR: 120°30'40"
SD* 131.678 m
MEAS MODE NP/P P1
HR: 120°30'40"
SD* 131.678 m
MEAS MODE NP/P P1
↓