Topcon Marine Instruments GPT-2000 Manuel D’Utilisation

Page de 168
   6 SPECIAL MODE (Menu Mode)
6-14
6.1.5 Point to Line Measurement
This mode is used to obtain the coordinate data with the origin  point  A(0,0,0) and the line AB as N 
axis. 
Place the 2 prisms at the points A and B on the line, and place the instrument at unknown point C. After 
measuring the 2 prisms , the coordinate data and the direction angle of the instrument will be calculated 
and restored.
Operating procedure
Operation
Display
1
After pressing the [MENU] key, press the [F4](P
key to get the menu on page 2/3.
[MENU]
[F4]
2
Press the [F1] key.
[F1]
3
Press the [F4](P
) key to get the PROGRAMS 
menu on page 2/2.
[F4]
4
Press the [F2] key.
[F2]
5
Press the [F1](INPUT) key and enter instrument  
height.
[F1]
Enter 
INS.HT
[F4]
6
Press the [F1](INPUT) key and enter reflector 
A(P1) height.
[F1]
Enter R.HT
[F4]
P(n, e, z)
Prism P2
Line
Instrument Point (Unknown point)
INS.HT
Prism P1
R.HT
  
MENU            2/3
 F1:PROGRAMS
 F2:GRID FACTOR
 F3:ILLUMINATION P
  
PROGRAMS        1/2
 F1:REM 
 F2:MLM
 F3:Z COORD.     P
  
PROGRAMS        2/2
 F1:AREA
 F2:POINT TO LINE
                 P
  
INSTRUMENT HEIGHT
INPUT
INS.HT:    0.000 m
INPUT –––  ––– ENTER
  
REFLECTOR HEIGHT
INPUT
R.HT:      0.000 m
INPUT –––  ––– ENTER
  
POINT TO LINE
MEAS.P1
 HD:             m
MEAS  –––  NP/P –––