6.1.4 Data 
port 
The data port(s) are implemented as Data Communications Equipment (DCE). The connector 
used are female 9-pin D-subs. 
 
NOTE!  Data port 2 is used by both Wave II Camera and Precision HD Camera and has different 
pin-out scheme for the different use. 
 
The TANDBERG main camera is normally connected to data port 2 and pin number 4 provides 
12V DC / 1 Amps to the main camera. Otherwise the pin-outs for both data ports are the same. 
 
Signal name 
Direction 
Pin number 
Carrier detect, CD 
From DCE 
Receive data, RXD 
From DCE 
Transmit data, TXD 
To DCE 
Data terminal ready, DTR 
From DCE 
Signal ground, GND 
 
Data set ready, DSR 
From DCE 
Ready to send, RTS 
To DCE 
Clear to send, CTS 
From DCE 
Ring indicator, RI 
From DCE 
 
 
Data Port 2 with Precision HD Camera 
Pin-outs for the THSI (TANDBERG High Speed Interface) on data port 2: 
 
Signal name 
Direction 
Pin number 
Receive video + 
To DCE 
Receive data, RXD 
From DCE 
Transmit data, TXD 
To DCE 
Power, 12V 
 
Signal ground, GND 
 
Receive video - 
To DCE