Omni Group Step Top Wood Stove 57ST-ACC Manuel D’Utilisation

Page de 52
Page  10
7038-159D
November 28, 2011
R
5700 Step Top Wood Stove Series ACC
I.  Air Controls
1. Start-Up Air Control
The Start-Up Air Control has two primary functions. 
The  fi rst  function  is  to  activate  the Automatic  Combustion 
Control system (ACC).
•  Slide the Start-Up Air Control all the way back until it stops 
at the “HI” indicator on the label and then pull forward to 
the front of the appliance until it stops. Figure 10.1.
 •  The front air channel opens and allows air to enter the front 
of the appliance for approximately 25 minutes.
•  The front air channel gradually shuts down until it is com-
pletely closed at the end of the 25 minutes.
•  The fi re is now controlled by the air supplied by the Burn 
Rate Air Control. Figure 10.1.
•  This function should be performed each time you reload 
the appliance.
The second function of the Start-Up Air Control is operation 
of the rear air system.
•  Slide the Start-Up Air Control between the fi rst and third 
marker as indicated on the label to allow rear air to enter 
the fi rebox.  Figure 10.1.
•  The rear air is used primarily during a High Burn Rate.
•  In some instances rear air is desired during normal opera-
tion to help with combustion of fuel towards the back of 
the fi rebox particularly when burning hardwoods. 
•  The  rear  air  is  controlled  independently  from  the ACC 
system.
Figure 10.1 - Start-Up and Burn Rate Air Controls
HIGH 
MED 
LOW 
Burn Rate 
Air Control 
Start-Up 
Air Control 
Manual 
Timer (ACC) 
Shut Down 
Pull Forward 
to Shut Down 
Figure 10.2 - Manual Over-Ride
2.  Manual Timer Over-Ride
If you need to shut the ACC system off before it shuts itself 
off  after  25  minutes  (i.e.  overfi re  situation),  reach  down  to 
the  bottom  right  rear  corner  and  pull  the  lever  toward  you.  
Figure 10.
2.  
3.  Burn Rate Air Control
• 
The  air  supply  enters  at  the  upper  front  of  the  fi rebox, 
near the top of the glass door. 
• 
This preheated air supplies the necessary fresh oxygen 
to  mix  with  the  unburned  gases,  helping  to  create  sec-
ond, third and fourth combustions
H.  Automatic Combustion Control (ACC)
Typically, when you build a fi re, you open the air controls fully 
and monitor the fi re to prevent it from going into an overfi re 
situation and/or burning your wood up too quickly before you 
shut down the air controls to the desired burn rate.  
When using the Automatic Combustion Control (ACC) system, 
you  do  not  have  to  continually  monitor  the  fi re.    Once  you 
set the ACC system it will control the fi re for you.  Follow the 
instructions  below  to  learn  how  to  operate  your  stove  with 
ease.
•  This air is regulated by the Burn Rate Air Control.  
• 
There  are  four  settings  High,  Medium-High,  Medium-
Low and Low.
• 
When  the  control  is  raised  all  the  way  up  it  is  on  the 
High setting and when pushed all the down it is on the 
Low setting. Figure 11.1 on page 11.
3.  Burn Rate Air Control (Cont’d)